66
3.
Wait until you see the following message:
DCX:FID128:admin>
sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y
HA is disabled
Stopping blade 10
Shutting down the blade....
Stopping blade 12
Shutting down the blade....
Broadcast message from root (pts/0) Fri Oct 10 08:36:48 2008...
The system is going down for system halt NOW !!
4.
Power off the switch.
High availability of daemon processes
Fabric OS 6.0 supports automatic restart of non-critical daemons. Starting these non-critical daemons is
automatic; you cannot configure the startup process. The following sequence of events occurs when a
non-critical daemon fails:
1.
A RASlog and AUDIT event message is logged.
2.
The daemon is automatically started again.
3.
If the restart is successful, another message is sent to RASlog and AUDIT reporting the successful restart
status.
4.
If the restart fails, another message is sent to RASlog and no further attempts are made to restart the
daemon.
Schedule downtime and reboot the switch at your convenience. The following table lists the daemons that
are considered non-critical and are automatically restarted on failure.
Table 7
Daemons that are automatically restarted
Daemon Description
arrd
Asynchronous Response Router (used to send management data to hosts when the switch is
accessed through the APIs (FA API or SMI-S).
cald
Common Access Layer Daemon (used by Manageability Applications).
raslogd
Reliability, Availability, and Supportability daemon logs error detection, reporting, handling,
and presentation of data into a format readable by management tools and the user.
rpcd
Remote Procedure Call daemon used by the API (Fabric Access API and SMI-S).
scpd
SAS CP daemon.
snmpd
Simple Network Management Protocol Daemon.
traced
Trace Daemon. Provide trace entry date/time translation to Trace Device at startup and when
date/time changed by command. Maintains the trace dump trigger parameters in a Trace
Device. Performs the trace Background Dump, trace automatic FTP, and FTP “aliveness check” if
auto-FTP is enabled.
trackd
Track Changes Daemon.
webd
Webserver daemon used for WebTools (includes httpd as well).
Summary of Contents for A7533A - Brocade 4Gb SAN Switch Base
Page 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Page 24: ...24 ...
Page 99: ...Fabric OS 6 2 administrator guide 99 ...
Page 100: ...100 Managing user accounts ...
Page 118: ...116 Configuring standard security features ...
Page 164: ...162 Configuring advanced security features ...
Page 234: ...232 Installing and maintaining firmware ...
Page 268: ...266 Administering advanced zoning ...
Page 284: ...282 Configuring Enterprise class platforms ...
Page 292: ...290 Routing traffic ...
Page 294: ...292 Interoperability for merged SANs ...
Page 302: ...300 Configuring the Distributed Management Server ...
Page 334: ...332 iSCSI gateway service ...
Page 340: ...338 Administering NPIV ...
Page 407: ...Fabric OS 6 2 administrator guide 405 ...
Page 408: ...406 Using the FC FC routing service ...
Page 438: ...434 Administering extended fabrics ...
Page 460: ...456 Administering ISL trunking ...
Page 516: ...512 FICON fabrics ...
Page 526: ...522 Configuring and monitoring FICON Extension Services ...
Page 540: ...536 Configuring the PID format ...
Page 544: ...540 Understanding legacy password behavior ...
Page 546: ...542 Mixed fabric configurations for non merge SANs ...
Page 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Page 558: ...554 Inband Management ...
Page 572: ...568 ...