Fabric OS 6.2 administrator guide 229
5.
Exit the session.
6.
Update the firmware on the standby CP:
a.
Connect to the enterprise-class platform and log in as admin to the standby CP.
b.
Enter the
firmwareDownload -s
command and respond to the prompts.
At this point, the firmware should download to the standby CP only. When it has completed the
download to that CP, reboot it. The current enterprise-class platform session will be disconnected.
7.
Fail over to the standby CP.
a.
Connect to the enterprise-class platform on the active CP.
b.
Enter the
haShow
command to verify that HA synchronization is complete. It will take a minute or
two for the standby CP to reboot and synchronize with the active CP.
CAUTION:
If you are downgrading from Fabric OS 6.2.0 to 6.1.0, your CPs will not gain synchronization
and this will be a disruptive firmware download. See
Table 56
on page 215 for more information on
synchronization states.
c.
Enter the
firmwareShow
command to confirm that the primary partition of the standby CP
contains the new firmware.
d.
Enter the
haFailover
command. The active CP will reboot and the current enterprise-class
platform session will be disconnected.
If an AP blade is present:
At the point of the failover an
autoleveling
process is activated. See,
”
Enterprise-class platform firmware download process overview
” on page 220 for details about
autoleveling.
8.
Verify the failover:
a.
Connect to the enterprise-class platform on the active CP, which is the former standby CP.
b.
Enter the
haShow
command to verify that the HA synchronization is complete. It will take a minute
or two for the standby CP, which is the old active CP, to reboot and synchronize with the active CP.
NOTE:
If the CPs fail to synchronize, you can still proceed because the version being tested is
already present on the active CP, and subsequent steps will ensure that the standby CP is updated to
the same version as the active CP.
c.
Confirm the evaluation version of firmware is now running on the active CP by entering the
firmwareShow
command.
9.
Update firmware on the standby CP:
a.
Connect to the enterprise-class platform on the standby CP, which is the old active CP.
b.
Enter the
firmwareDownload -s
command and respond to the prompts.
At this point the firmware should download to the standby CP only and reboot it. The current
enterprise-class platform session will be disconnected.
c.
Wait one minute for the standby CP to reboot, and then connect to the enterprise-class platform and
log in as admin.
d.
Enter the
firmwareShow
command to confirm that
both
primary partitions now have the test drive
firmware in place.
You are now ready to evaluate the new version of firmware.
IMPORTANT:
Stop!
If you want to
restore
the firmware, stop here
and skip ahead to
step 12
;
otherwise, continue to
step 10
to commit the firmware on both CPs, which completes the firmware
download.
Summary of Contents for A7533A - Brocade 4Gb SAN Switch Base
Page 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Page 24: ...24 ...
Page 99: ...Fabric OS 6 2 administrator guide 99 ...
Page 100: ...100 Managing user accounts ...
Page 118: ...116 Configuring standard security features ...
Page 164: ...162 Configuring advanced security features ...
Page 234: ...232 Installing and maintaining firmware ...
Page 268: ...266 Administering advanced zoning ...
Page 284: ...282 Configuring Enterprise class platforms ...
Page 292: ...290 Routing traffic ...
Page 294: ...292 Interoperability for merged SANs ...
Page 302: ...300 Configuring the Distributed Management Server ...
Page 334: ...332 iSCSI gateway service ...
Page 340: ...338 Administering NPIV ...
Page 407: ...Fabric OS 6 2 administrator guide 405 ...
Page 408: ...406 Using the FC FC routing service ...
Page 438: ...434 Administering extended fabrics ...
Page 460: ...456 Administering ISL trunking ...
Page 516: ...512 FICON fabrics ...
Page 526: ...522 Configuring and monitoring FICON Extension Services ...
Page 540: ...536 Configuring the PID format ...
Page 544: ...540 Understanding legacy password behavior ...
Page 546: ...542 Mixed fabric configurations for non merge SANs ...
Page 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Page 558: ...554 Inband Management ...
Page 572: ...568 ...