Fabric OS 6.2 administrator guide 269
Port Identification by Port Area ID
The relationship between the port number and area ID depends upon the PID format used in the fabric.
When Core PID format is in effect, the area ID for port 0 is 0, for port 1 is 1, and so forth.
For 32-port blades (HP StorageWorks 4/256 SAN Director 16 Port 4Gb blade, HP StorageWorks SAN
Director 32 Port 8Gb FC blade), the numbering is contiguous up to port 15; from port 16, the numbering is
still contiguous, but starts with 128. For example, port 15 in slot 1 has a port number and area ID of 15;
port 16 has a port number and area ID of 128; port 17 has a port number and area ID of 129.
For 48-port blades (HP StorageWorkds 4/256 SAN Director 48 Port 4Gb blade, HP StorageWorks SAN
Director 48 Port 8Gb FC blade), the numbering is the same as for 32-port blades for the first 32 ports on
the blade. For ports 32 through 47, area IDs are not unique and port index should be used instead of area
ID.
If you perform a port swap operation, the port number and area ID no longer match. On 48-port blades,
port swapping is supported only on ports 0–15.
To determine the area ID of a particular port, enter the
switchShow
command. This command displays
all ports on the current (logical) switch and their corresponding area IDs.
Port identification by index
With the introduction of 48-port blades, indexing was introduced. Unique area IDs are possible for up to
255 areas, but beyond that there needed to be some way to ensure uniqueness.
A number of fabric-wide databases supported by Fabric OS (including ZoneDB, the ACL DDC, and Admin
Domain) allow a port to be designated by the use of a “D,P” (
domain,port
) notation. While the “P”
component appears to be the port number, in up to 255 ports it is actually the
area
assigned to that port.
IMPORTANT:
The port area schema does not apply to the HP StorageWorks DC04 SAN Director Switch
enterprise-class platform.
If the PID format is changed from Extended-edge to Core, the “P” value for ports 0-127 also changes. If two
ports are changed using the
portSwap
command, their respective areas and “P” values are exchanged.
For ports that are numbered above 255, the “P” value is actually a logical index. The first 256 ports
continue to have an index value equal to the area_ID assigned to the port. If a switch is using Core PID
format, and no port swapping has been done, the port Index value for all ports is the same as the physical
port numbers. Using
portSwap
on a pair of ports will exchange those ports’ area_ID and index values.
NOTE:
The
portSwap
command is not supported for ports above 256.
Table 68
shows the area ID and index mapping for core PID assignment for the HP StorageWorks 4/256
SAN Director and the HP StorageWorks DC SAN Backbone Director enterprise-class platform. There are
up to 255 areas and the area_ID mapping to the index is one-to-one. Beyond this, the index is similar but
not exact, and in some instances, the area ID is shared among multiple ports.
This table provides the area_ID/index assignment for the maximum number of ports used by the HP
StorageWorks 4/256 SAN Director 48 Port 4Gb blade and HP StorageWorks SAN Director 48 Port 8Gb
FC blade. If your blade does not have the maximum number of ports, use the lower sections of the table to
determine the area_ID and index.
Table 68
Default index/area_ID core PID assignment with no port swap
Port
on
blade
Slot
1Idx/are
a
Slot
2Idx/are
a
Slot
3Idx/are
a
Slot
4Idx/are
a
Slot
7Idx/are
a
Slot
8Idx/are
a
Slot
9Idx/are
a
Slot
10Idx/area
47
271/135
287/151
303/167
319/183
335/199
351/215
367/231
383/247
46
270/134
286/150
302/166
318/182
334/198
350/214
366/230
382/246
Summary of Contents for A7533A - Brocade 4Gb SAN Switch Base
Page 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Page 24: ...24 ...
Page 99: ...Fabric OS 6 2 administrator guide 99 ...
Page 100: ...100 Managing user accounts ...
Page 118: ...116 Configuring standard security features ...
Page 164: ...162 Configuring advanced security features ...
Page 234: ...232 Installing and maintaining firmware ...
Page 268: ...266 Administering advanced zoning ...
Page 284: ...282 Configuring Enterprise class platforms ...
Page 292: ...290 Routing traffic ...
Page 294: ...292 Interoperability for merged SANs ...
Page 302: ...300 Configuring the Distributed Management Server ...
Page 334: ...332 iSCSI gateway service ...
Page 340: ...338 Administering NPIV ...
Page 407: ...Fabric OS 6 2 administrator guide 405 ...
Page 408: ...406 Using the FC FC routing service ...
Page 438: ...434 Administering extended fabrics ...
Page 460: ...456 Administering ISL trunking ...
Page 516: ...512 FICON fabrics ...
Page 526: ...522 Configuring and monitoring FICON Extension Services ...
Page 540: ...536 Configuring the PID format ...
Page 544: ...540 Understanding legacy password behavior ...
Page 546: ...542 Mixed fabric configurations for non merge SANs ...
Page 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Page 558: ...554 Inband Management ...
Page 572: ...568 ...