Fabric OS 6.2 administrator guide 487
The following example adds an entry that tags all frames from IP address 192.168.10.1 destined for IP
address 192.168.20.1 with a VLAN ID of 100, and a L2 CoS value of 3.
switch:admin>
portcfg vlantag 8/ge0 add 192.168.10.1 100 3 7 192.168.20.1
WAN performance analysis tools
Introduced in Fabric OS 5.2.0, WAN analysis tools are designed to test connections, trace routes, and
estimate the end-to-end IP path performance characteristics between a pair of B-Series FCIP port endpoints.
WAN tools include the following commands and options:
•
portCmd
--
ipPerf
characterizes end-to-end IP path performance between a pair of B-Series FCIP
ports.
•
portCmd
--
ping
tests connections between a local Ethernet port (ge0 or ge1) and a destination IP
address.
•
portCmd
--
traceroute
traces routes from a local Ethernet port (ge0 or ge1) to a destination IP
address.
•
portShow fcipTunnel -perf
displays performance statistics generated from the WAN analysis.
ipPerf option
The WAN tool
ipPerf
(referred to simply as
ipPerf
in this chapter) is an option of the Fabric OS
portCmd
command. This option allows you to specify the slot and port information for displaying performance
statistics for a pair of ports. For this basic configuration, you can specify the IP addresses of the endpoints,
target bandwidth for the path, and optional parameters such as the length of time to run the test and
statistic polling interval.
Only a single
ipPerf
session can be active on an FCIP GbE port at any time. Each FCIP port supports a
single instance of the WAN tool-embedded client running in sender or receiver mode only. You can,
however, use multiple CLI sessions to invoke simultaneous
ipPerf
sessions on different FCIP ports.
WAN tool sessions with an FCIP tunnel online
ipPerf
sessions use different TCP ports than FCIP tunnels, so you can simultaneously run an
ipPerf
session between a pair of ports while an FCIP tunnel is online. You can, for example, revalidate the service
provider Service Level Agreement (SLA) without bringing the FCIP tunnel down, but the general
recommendation is to run
ipPerf
only when there are no active tunnels on the IP network. Data
transferred across an active FCIP tunnel competes for the same network bandwidth as the
ipPerf
session,
and
ipPerf
is attempting to saturate a network to determine how much usable bandwidth is available
between the sites. Unless you have a method to quiesce all storage traffic over an active FCIP tunnel during
ipPerf
testing, you may experience undesirable interactions.
FCIP port bandwidth
Allocation of the FCIP GbE port bandwidth behaves exactly the same for
ipPerf
as for FCIP tunnels.If
bandwidth is allocated for FCIP tunnels, the
ipPerf
session uses the remaining bandwidth. Since
bandwidth is already reserved for the FCIP tunnels, the
ipPerf
session is not affected by any active FCIP
tunnel. If no bandwidth is reserved, the
ipPerf
session competes for a share of the uncommitted
bandwidth. Starting an
ipPerf
session has an impact on any active uncommitted bandwidth FCIP tunnels
just like adding a new FCIP tunnel would. For example:
•
Adding a committed-rate
ipPerf
session reduces the total uncommitted bandwidth shared by all the
uncommitted bandwidth FCIP tunnels.
•
Adding an uncommitted-bandwidth
ipPerf
session adds another flow competing for the shared
uncommitted bandwidth.
The CLI and configuration system ensures that any bandwidth allocation does not result in an over
commitment of the FCIP GbE port. An active FCIP tunnel cannot be forced to give up its committed buffer
and bandwidth resources. Therefore, to commit a specific bandwidth to the
ipPerf
session, you must have
an equivalent amount of spare capacity on the FCIP GbE port.
Summary of Contents for A7533A - Brocade 4Gb SAN Switch Base
Page 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Page 24: ...24 ...
Page 99: ...Fabric OS 6 2 administrator guide 99 ...
Page 100: ...100 Managing user accounts ...
Page 118: ...116 Configuring standard security features ...
Page 164: ...162 Configuring advanced security features ...
Page 234: ...232 Installing and maintaining firmware ...
Page 268: ...266 Administering advanced zoning ...
Page 284: ...282 Configuring Enterprise class platforms ...
Page 292: ...290 Routing traffic ...
Page 294: ...292 Interoperability for merged SANs ...
Page 302: ...300 Configuring the Distributed Management Server ...
Page 334: ...332 iSCSI gateway service ...
Page 340: ...338 Administering NPIV ...
Page 407: ...Fabric OS 6 2 administrator guide 405 ...
Page 408: ...406 Using the FC FC routing service ...
Page 438: ...434 Administering extended fabrics ...
Page 460: ...456 Administering ISL trunking ...
Page 516: ...512 FICON fabrics ...
Page 526: ...522 Configuring and monitoring FICON Extension Services ...
Page 540: ...536 Configuring the PID format ...
Page 544: ...540 Understanding legacy password behavior ...
Page 546: ...542 Mixed fabric configurations for non merge SANs ...
Page 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Page 558: ...554 Inband Management ...
Page 572: ...568 ...