416 Administering advanced performance monitoring
where:
The output is sorted based on the data rate of each flow. If you do not specify the number of flows to
display, the command displays the top eight flows or the total number of flows, whichever is less.
For example, to display the top 5 flows on port 7 in WWN (default) format:
perfttmon --show 7 5
To display the top flows on slot 2, port 4 on the BHP StorageWorks 4/256 SAN Director, HP
StorageWorks DC SAN Backbone Director, or HP StorageWorks DC04 SAN Director Switch in PID
format:
perfttmon --show 2/4 pid
switch:admin>
perfttmon --show 2/4 pid
========================================
Src_PID
Dst_PID
MB/sec
========================================
0xa90800
0xa05200
6.926
0xa90800
0xa908ef
6.872
Adding Top Talker monitors on all switches in the fabric (fabric mode)
When fabric mode is enabled, you can no longer install Top Talker monitors on an F_Port unless you first
delete fabric mode.
1.
Connect to the switch and log in as admin.
2.
Remove any end-to-end monitors in the fabric, as described in ”
Deleting end-to-end monitors
” on
page 410. Fabric Mode Top Talker monitors and end-to-end monitors cannot both exist in the fabric.
3.
Enter the
perfTTmon
--
add fabricmode
command.
perfttmon --add fabricmode
The system responds:
Before enabling fabric mode, please remove all EE monitors in the fabric
continue? (yes, y, no, n):
4.
Enter
y
to continue.
Top Talker monitors are added to E_Ports in the fabric and fabric mode is enabled. Any Top Talker
monitors that were already installed on F_Ports are automatically uninstalled.
If end-to-end monitors are present on the local switch, the command fails with the message:
Cannot install Fabric Mode Top Talker because EE monitor is already
present
slotnumber
For enterprise-class platforms only (HP StorageWorks 4/256 SAN Director, HP
StorageWorks DC SAN Backbone Director, and HP StorageWorks DC04 SAN
Director Switch), the slot number.
port
The port number
n
The number of top talking flows to display, between 1 and 32. The maximum
number of flows that are actually displayed depends on the platform:
32
For HP StorageWorks 8/8 and 8/24 SAN Switches, HP StorageWorks
8/40 SAN Switch, HP StorageWorks 8/80 SAN Switch, and FC8-xx port
blades
16
For HP StorageWorks SAN Switch 4/32, HP StorageWorks 4/64 SAN
Switch, HP StorageWorks SAN Switch 4/32B, HP StorageWorks 400
Multi-Protocol Router, and FC4-xx port blades
wwn | pid
The format of the output. The default is
wwn
.
Summary of Contents for A7533A - Brocade 4Gb SAN Switch Base
Page 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Page 24: ...24 ...
Page 99: ...Fabric OS 6 2 administrator guide 99 ...
Page 100: ...100 Managing user accounts ...
Page 118: ...116 Configuring standard security features ...
Page 164: ...162 Configuring advanced security features ...
Page 234: ...232 Installing and maintaining firmware ...
Page 268: ...266 Administering advanced zoning ...
Page 284: ...282 Configuring Enterprise class platforms ...
Page 292: ...290 Routing traffic ...
Page 294: ...292 Interoperability for merged SANs ...
Page 302: ...300 Configuring the Distributed Management Server ...
Page 334: ...332 iSCSI gateway service ...
Page 340: ...338 Administering NPIV ...
Page 407: ...Fabric OS 6 2 administrator guide 405 ...
Page 408: ...406 Using the FC FC routing service ...
Page 438: ...434 Administering extended fabrics ...
Page 460: ...456 Administering ISL trunking ...
Page 516: ...512 FICON fabrics ...
Page 526: ...522 Configuring and monitoring FICON Extension Services ...
Page 540: ...536 Configuring the PID format ...
Page 544: ...540 Understanding legacy password behavior ...
Page 546: ...542 Mixed fabric configurations for non merge SANs ...
Page 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Page 558: ...554 Inband Management ...
Page 572: ...568 ...