Fabric OS 6.2 administrator guide 143
NOTE:
FC routers cannot join a fabric with a strict fabric-wide consistency policy. FC routers do not
support the fabric-wide consistency policies.
Table 37
on page 143 describes the fabric-wide consistency settings.
Displaying the fabric-wide consistency policy
1.
Connect to the switch and log in using an account assigned to the admin role.
2.
Enter the
fddCfg --showall
command.
The following example shows policies for a fabric where no consistency policy is defined.
switch:admin>
fddcfg --showall
Local Switch Configuration for all Databases:-
DATABASE - Accept/Reject
---------------------------------
SCC - accept
DCC - accept
PWD - accept
FCS - accept
AUTH - accept
IPFILTER - accept
Fabric Wide Consistency Policy:- ""
Setting the fabric-wide consistency policy
1.
Connect to the switch and log in using an account assigned to the admin role.
2.
Enter the following command:
fddCfg --fabwideset "<policy_ID>"
where
policy_ID
is a semicolon-separated list
database_setting
;
database_setting
equal to:
Table 37
Fabric-wide consistency policy settings
Setting
Value
When a policy is activated
Absent
null
Database is not automatically distributed to other switches in the fabric.
Tolerant
database_id
All updated and new policies of the type specified (SCC, DCC, or both)
are distributed to all Fabric 5.2.0 and later switches in the fabric.
Pre-Fabric OS 5.2.0 switches are allowed in the fabric, but no
automated means are provided to ensure that those switches have
consistent databases. A warning is displayed if the databases do not
match.
Strict
database_id
:S
All updated and new policies of the type specified (SCC, DCC, or both)
are distributed to all switches in the fabric.
null
Excludes the database ID from the list to set the policy to absent.
database_id
Sets a tolerant policy for a database. The database ID is either SCC, DCC, or FCS.
database_id:S
Sets the policy to
strict
. The database ID is either SCC, DCC, or FCS.
Summary of Contents for A7533A - Brocade 4Gb SAN Switch Base
Page 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Page 24: ...24 ...
Page 99: ...Fabric OS 6 2 administrator guide 99 ...
Page 100: ...100 Managing user accounts ...
Page 118: ...116 Configuring standard security features ...
Page 164: ...162 Configuring advanced security features ...
Page 234: ...232 Installing and maintaining firmware ...
Page 268: ...266 Administering advanced zoning ...
Page 284: ...282 Configuring Enterprise class platforms ...
Page 292: ...290 Routing traffic ...
Page 294: ...292 Interoperability for merged SANs ...
Page 302: ...300 Configuring the Distributed Management Server ...
Page 334: ...332 iSCSI gateway service ...
Page 340: ...338 Administering NPIV ...
Page 407: ...Fabric OS 6 2 administrator guide 405 ...
Page 408: ...406 Using the FC FC routing service ...
Page 438: ...434 Administering extended fabrics ...
Page 460: ...456 Administering ISL trunking ...
Page 516: ...512 FICON fabrics ...
Page 526: ...522 Configuring and monitoring FICON Extension Services ...
Page 540: ...536 Configuring the PID format ...
Page 544: ...540 Understanding legacy password behavior ...
Page 546: ...542 Mixed fabric configurations for non merge SANs ...
Page 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Page 558: ...554 Inband Management ...
Page 572: ...568 ...