Fabric OS 6.2 administrator guide 517
FICON emulation configuration values
You can display the values configured for FICON emulation by issuing the
portShow ficon
command.
The following example shows FICON emulation configuration values for port ge1:
Sprint108:root>
portshow ficon ge1 all
Port: ge1
VE_STATUS
TunnelId vePort vePortStatus veFeatureBitMap veHashEntryCount
0 24 UP 1 2
1 ff DOWN 0 0
2 ff DOWN 0 0
3 ff DOWN 0 0
4 ff DOWN 0 0
5 ff DOWN 0 0
6 ff DOWN 0 0
7 ff DOWN 0 0
FEATURES
TunnelId XRC TapeWrt TapeRd TinTir DvcLack RdBlkId
0 ON ON ON ON ON OFF
1 OFF OFF OFF OFF OFF OFF
2 OFF OFF OFF OFF OFF OFF
3 OFF OFF OFF OFF OFF OFF
4 OFF OFF OFF OFF OFF OFF
5 OFF OFF OFF OFF OFF OFF
6 OFF OFF OFF OFF OFF OFF
7 OFF OFF OFF OFF OFF OFF
PARAMETERS
TunnelId WrtPipe RdPipe WrtDevs RdDevs WrtTimer WrtChain OxidBase DebugFlags
0 032 032 16 16 0300 3000000 0x7000 0xffc80000
1 000 000 00 00 0000 0000000 0x0000 0x00000000
2 000 000 00 00 0000 0000000 0x0000 0x00000000
3 000 000 00 00 0000 0000000 0x0000 0x00000000
4 000 000 00 00 0000 0000000 0x0000 0x00000000
5 000 000 00 00 0000 0000000 0x0000 0x00000000
6 000 000 00 00 0000 0000000 0x0000 0x00000000
7 000 000 00 00 0000 0000000 0x0000 0x00000000
FICON emulation modification
Following is the syntax for the
portcfg ficon modify
command:
portCfg ficon [slot/]ge0|ge1 tunnel_Id modify [-x 1|0] [-w 1|0] [-r 1|0] [-t 1|0]
[-l 1|0] [-b 1|0] [wrtMaxPipe value] [rdMaxPipe value] [wrtMaxDevs value]
[rdMaxDevs value]
[wrtTimer value] [wrtMaxChains value] [oxidBase value] [dbgFlags value] [xrcErr]
[LrcCheck]
where:
•
slot
is the number of a slot in a 4/256 SAN Director or DC Director chassis that contains a B-Series
Multi-protocol Router blade. This parameter does not apply to the stand-alone 400 MP Router.
•
ge0|ge1
is the Ethernet port used by the tunnel (ge0 or Ge1).
•
tunnel_id
is the tunnel number (0 - 7).
•
modify
is the modify option that changes the FICON emulation configuration options and
parameters.
The following options turn features on and off. The associates tunnels must be disabled to modify the option
settings. If you attempt to do them on an enabled tunnel, the operation is not allowed, and you are
prompted to disable the tunnel.
•
-x
1|0
enables or disables XRC emulation. 1 is enable, O is disable.
•
-w
1|0
enables or disables tape write pipelining. 1 is enable, O is disable.
Summary of Contents for A7533A - Brocade 4Gb SAN Switch Base
Page 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Page 24: ...24 ...
Page 99: ...Fabric OS 6 2 administrator guide 99 ...
Page 100: ...100 Managing user accounts ...
Page 118: ...116 Configuring standard security features ...
Page 164: ...162 Configuring advanced security features ...
Page 234: ...232 Installing and maintaining firmware ...
Page 268: ...266 Administering advanced zoning ...
Page 284: ...282 Configuring Enterprise class platforms ...
Page 292: ...290 Routing traffic ...
Page 294: ...292 Interoperability for merged SANs ...
Page 302: ...300 Configuring the Distributed Management Server ...
Page 334: ...332 iSCSI gateway service ...
Page 340: ...338 Administering NPIV ...
Page 407: ...Fabric OS 6 2 administrator guide 405 ...
Page 408: ...406 Using the FC FC routing service ...
Page 438: ...434 Administering extended fabrics ...
Page 460: ...456 Administering ISL trunking ...
Page 516: ...512 FICON fabrics ...
Page 526: ...522 Configuring and monitoring FICON Extension Services ...
Page 540: ...536 Configuring the PID format ...
Page 544: ...540 Understanding legacy password behavior ...
Page 546: ...542 Mixed fabric configurations for non merge SANs ...
Page 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Page 558: ...554 Inband Management ...
Page 572: ...568 ...