408 Administering advanced performance monitoring
where:
Figure 71
shows two devices:
•
Host A is connected to domain 5 (0x05), switch area ID 18 (0x12), AL_PA 0x00 on Switch X.
•
Dev B is a storage device connected to domain 17 (0x11), switch area ID 30 (0x1e), AL_PA 0xef on
Switch Y.
Figure 71
Setting end-to-end monitors on a port
End-to-end performance monitoring looks at traffic on SID/DID pairs in any direction. That is, even if the
SID is for a remote device, the traffic is monitored in both directions (the Tx/Rx counters are reversed).
Monitoring the traffic from Host A to Dev B
Add Monitor 0 to slot 2, port 2 on Switch x, specifying 0x051200 as the SID and 0x111eef as the DID, as
shown in the following example:
switch:admin> perfaddeemonitor 2/2, "0x051200" "0x111eef"
End-to-End monitor number 0 added.
Monitor 0 counts the frames that have an SID of 0x051200 and a DID of 0x111eef. For monitor 0,
RX_COUNT is the number of words from Host A to Dev B, and TX_COUNT is the number of words from
Dev B to Host A.
Monitoring the traffic from Dev B to Host A
Add Monitor 1 to slot 2, port 14 on Switch y, specifying 0x111eef as the SID and 0x051200 as the DID, as
shown in the following example.
switch:admin> perfaddeemonitor 2/14, "0x111eef" "0x051200"
End-to-End monitor number 1 added.
Monitor 1 counts the frames that have an SID of 0x111eef and a DID of 0x051200. For monitor 1,
RX_COUNT is the number of words from Dev B to Host A, and TX_COUNT is the number of words from
Host A to Dev B.
Figure 72
shows several switches and the correct ports on which to add performance monitors for a
specified SID-DID pair.
Figure 72
Proper placement of end-to-end performance monitors
slotnumber
For bladed systems only, specifies the slot number of the port on which the monitor is
to be added. For all other switches, this operand is not required.
portnumber
Specifies the port number
sourceID
Specifies the 3-byte SID (source ID) of the originator device
destID
Specifies the 3-byte DID (destination ID) of the destination device
. . .
0x051200
0x111eef
Host
A
DID
SID
. . .
Dev
B
Switch X
Switch Y
Monitor 0
domain 0x05, switch area ID 0x12
AL_PA 0x00
Monitor 1
domain 0x11, switch area ID 0x1e
AL_PA 0xef
. . .
0x051200
Host
A
SID
. . .
. . .
. . .
Add monitors here
0x111eef
DID
Dev
B
Summary of Contents for A7533A - Brocade 4Gb SAN Switch Base
Page 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Page 24: ...24 ...
Page 99: ...Fabric OS 6 2 administrator guide 99 ...
Page 100: ...100 Managing user accounts ...
Page 118: ...116 Configuring standard security features ...
Page 164: ...162 Configuring advanced security features ...
Page 234: ...232 Installing and maintaining firmware ...
Page 268: ...266 Administering advanced zoning ...
Page 284: ...282 Configuring Enterprise class platforms ...
Page 292: ...290 Routing traffic ...
Page 294: ...292 Interoperability for merged SANs ...
Page 302: ...300 Configuring the Distributed Management Server ...
Page 334: ...332 iSCSI gateway service ...
Page 340: ...338 Administering NPIV ...
Page 407: ...Fabric OS 6 2 administrator guide 405 ...
Page 408: ...406 Using the FC FC routing service ...
Page 438: ...434 Administering extended fabrics ...
Page 460: ...456 Administering ISL trunking ...
Page 516: ...512 FICON fabrics ...
Page 526: ...522 Configuring and monitoring FICON Extension Services ...
Page 540: ...536 Configuring the PID format ...
Page 544: ...540 Understanding legacy password behavior ...
Page 546: ...542 Mixed fabric configurations for non merge SANs ...
Page 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Page 558: ...554 Inband Management ...
Page 572: ...568 ...