450
Chapter 10, Service Screen
Troubleshooting with the Service Screen
N:\mkt\MANUALS\HP8924C\ALR\service.fb
Troubleshooting with the Service Screen
The Service screen uses the internal voltmeter and frequency counter functions to
monitor specific nodes in most assemblies. A large number of latch and DAC
settings used throughout the Test Set can also be read and/or set to alter standard
operation. These functions are primarily intended to allow the automated internal
diagnostic routines to verify proper instrument operation, and to allow the
periodic adjustment routines (PER_CAL3, CDMA_CAL, and PCB_CAL) to
modify Test Set operation.
Access to these functions under manual control is provided to allow further
troubleshooting when the diagnostics cannot isolate a failure to a specific
assembly. To do this, you must understand how to operate the Test Set and,
especially, understand how the assemblies in the Test Set work together.
Detailed manual Test Set operation is provided in the User’s Guide. Refer to the
Block Diagram chapter in this manual for information on how the overall
instrument, and each module, works.
How to Access the Service Screen
1. Press PRESET to preset the Test Set.
2. Press the SHIFT key, then press the TESTS key to access the CONFIGURE screen.
3. Select the SERVICE field in bottom-right corner of the screen (“To Screen” menu).
Summary of Contents for 8924E
Page 52: ...Contents 52 N mkt MANUALS HP8924C ALR 8924CE TOC A Error Messages ...
Page 53: ...Contents 53 N mkt MANUALS HP8924C ALR 8924CE TOC Index 633 ...
Page 54: ...Contents 54 N mkt MANUALS HP8924C ALR 8924CE TOC ...
Page 137: ...137 N mkt MANUALS HP8924C ALR per_adj fb 4 Periodic Adjustments ...
Page 449: ...449 N mkt MANUALS HP8924C ALR service fb 10 Service Screen ...
Page 455: ...455 N mkt MANUALS HP8924C ALR blkdia fb 11 Block Diagrams ...
Page 522: ...522 Chapter 11 Block Diagrams Assembly Details N mkt MANUALS HP8924C ALR blkdia fb ...
Page 613: ...613 N mkt MANUALS HP8924C ALR errmssg fb A Error Messages ...