192
Chapter 5, HP 8924C Performance Verification
Oscilloscope Performance Test 20
N:\mkt\MANUALS\HP8924C\ALR\24c_pt.fb
Procedure
1. Access the AF ANALYZER screen.
2. Set the
Filter 2
field to
>99 kHz LP
, and set the
AF Anl In
field to
Audio
In
.
3. Access the OSCILLOSCOPE screen.
4. Adjust the audio analyzer’s source until the digital voltmeter reads 5 V. Adjust the
frequency to the frequencies shown in the PTR (
see "Oscilloscope Performance Test
5. Adjust the
Time/Div
field to display 2 to 3 waveforms each time the frequency is
changed. (The
Time/Div
field is displayed when the
Controls
field is set to
Main
.)
6. Set the
Controls
field to
Marker
. Select the
Peak +
field (located under
Marker To
) to move the marker to the peak of the waveform. Repeat this step each
time the frequency is changed.
7. Read the
Marker Lvl
and compare the reading to the limits shown in the PTR.
Lvl
Time
To Screen
Marker To
Marker To
Position
Controls
OSCILLOSCOPE
Marker
Select Marker
Select Peak +
Level Results
AF Anl In
Filter 1
De-Emphasis
Detector
To Screen
TX Frequency
TX Power
AF ANALYZER
AC Level
Filter 2
Settling
Pk Det To
Speaker Vol
Speaker ALC
Scope To
Gain Cntl
Input Gain
Notch Gain
Notch Freq
De-Emp Gain
Audio In Lo
Ext Load R
DC Current
AF Cnt Gate
Select >99kHz LP
Select AF Anl In
Controls
Vert/div
Vert Offset
Time/div
Select Main
Adjust for
2 or 3
Waveforms
Summary of Contents for 8924E
Page 52: ...Contents 52 N mkt MANUALS HP8924C ALR 8924CE TOC A Error Messages ...
Page 53: ...Contents 53 N mkt MANUALS HP8924C ALR 8924CE TOC Index 633 ...
Page 54: ...Contents 54 N mkt MANUALS HP8924C ALR 8924CE TOC ...
Page 137: ...137 N mkt MANUALS HP8924C ALR per_adj fb 4 Periodic Adjustments ...
Page 449: ...449 N mkt MANUALS HP8924C ALR service fb 10 Service Screen ...
Page 455: ...455 N mkt MANUALS HP8924C ALR blkdia fb 11 Block Diagrams ...
Page 522: ...522 Chapter 11 Block Diagrams Assembly Details N mkt MANUALS HP8924C ALR blkdia fb ...
Page 613: ...613 N mkt MANUALS HP8924C ALR errmssg fb A Error Messages ...