To look at control and status signals during execution
of a routine
The state analyzer will trigger on the start of the routine whose control and
status signals are to be examined more frequently than once per bus cycle.
When the state analyzer triggers, it sends out an arm signal. The timing
analyzer triggers when it receives the true arm level and detects the
transition represented by Edge1.
1
Set up one state analyzer and one timing analyzer.
2
Go to the state analyzer’s Trigger menu and define term R_START to
represent the starting address of the routine.
3
Under State Sequence Levels, enter the following sequence
specification:
•
While storing "anystate" TRIGGER on "R_START" Occurs "1" Else on "no
state" go to level "1"
4
Go to the timing analyzer’s Trigger menu.
5
Define the Edge1 term to represent a transition on one of the control
signals.
6
Set the timing analyzer to be run by the state analyzer. Under Timing
Sequence Levels, enter the following sequence specification:
•
TRIGGER on "arm
•
Edge1" 1 time
You do not need to use a combination trigger when one analyzer is armed
from the other analyzer - the arm term is ANDed automatically with the term
already in use.
Cross-Arming Trigger Examples
To look at control and status signals during execution of a routine
5-24
Summary of Contents for 1660CS
Page 5: ...Introduction iv ...
Page 16: ...1 Logic Analyzer Overview ...
Page 24: ...2 Connecting Peripherals ...
Page 33: ...2 10 ...
Page 34: ...3 Using the Logic Analyzer ...
Page 55: ...3 22 ...
Page 56: ...4 Using the Trigger Menu ...
Page 75: ...4 20 ...
Page 76: ...5 Triggering Examples ...
Page 109: ...5 34 ...
Page 110: ...6 File Management ...
Page 119: ...6 10 ...
Page 120: ...7 Reference ...
Page 221: ...7 102 ...
Page 222: ...8 System Performance Analysis SPA Software ...
Page 241: ...SPA Time Interval System Performance Analysis SPA Software SPA measurement processes 8 20 ...
Page 252: ...9 Concepts ...
Page 284: ...10 Troubleshooting ...
Page 298: ...11 Specifications ...
Page 311: ...11 14 ...
Page 312: ...12 Operator s Service ...
Page 324: ...Troubleshooting Flowchart 2 Troubleshooting To use the flowcharts 12 13 ...
Page 337: ...Glossary 4 ...