Using Wavelink Avalanche to Upgrade System Baseline
This procedure assumes the Avalanche Enabler is already installed on the MX7 Tecton and is already in communication with
the Avalanche MC Console.
Part 1 – Bootstrapping the RMU
1. Install the RMUCEbt package into the Avalanche MC Console. Do NOT include the Reboot option as part of the
configuration (i.e. the
Reboot button
in the “Reboot Options” branch must be unbolded).
2. Enable ONLY the RMUCEbt package in the Avalanche MC Console and update the devices. The RMU is downloaded
and automatically installed.
3.
Disable
the RMUCEbt package in the Avalanche MC Console.
4. For each device,
double-click
on the device to open the Client Controls dialog box.
5. Check the
Delete Orphaned Packages
checkbox and click the
Update Now
button.
6. After the sync completes, uncheck
Delete Orphaned Packages
and close the dialog box.
Part 2 – Installing Packages
1.
Enable
the RMUCE package in the Avalanche MC Console.
2.
Enable
all remaining packages and send them down. It is important that you include the new OS package in this group
(be sure to include the Enabler). If the radio is to be managed remotely, it is important to include the radio package in this
group so that after the reboot the radio can automatically associate. If the radio package is not sent, the device loses
connection to the network and manual configuration of the radio parameters is required.
3. Set the Reboot setting for the OS package to
Auto
.
4. After all packages are downloaded (this may take several minutes) the Remote Management Utility is launched. The
RMU processes all the downloaded packages. If the radio package was downloaded, the Wireless Configuration
Application is launched to process the new radio settings.
5. After the RMU finishes installing all the packages, the device is automatically coldbooted (assuming the Reboot setting
was set to Auto in Step 3).
6. After the Device completes the coldboot, the RMU is autoinstalled by the OS and the previously downloaded packages
are restored. Assuming at least one package has registry settings that were restored, and that package was set to
reboot (either auto or prompt), the RMU then performs an automatic warmboot.
7. After the warmboot, the device is configured.
8. If the device will no longer be monitored by Wavelink Avalanche, you may remove the Enabler to eliminate boot up
delays, if desired. Even if the Enabler is removed, the installed packages and their configurations continue to be
restored with every reboot by the RMU.
7-6
Summary of Contents for MX7 Tecton
Page 14: ...xiv ...
Page 24: ...1 10 ...
Page 38: ...3 4 ...
Page 166: ...Hat Encoding Hat Encoded Characters Hex 00 through AD 4 128 ...
Page 167: ...Hat Encoded Characters Hex AE through FF 4 129 ...
Page 176: ...4 138 ...
Page 177: ...4 139 ...
Page 202: ...Enter user name password and domain to be used when logging into network resources 4 164 ...
Page 209: ...4 171 ...
Page 240: ...5 22 ...
Page 276: ...7 30 ...
Page 320: ...8 44 ...
Page 325: ...Click the Request a certificate link Click on the advanced certificate request link 8 49 ...
Page 326: ...Click on the Create and submit a request to this CA link 8 50 ...
Page 334: ...8 58 ...
Page 358: ...9 24 ...
Page 362: ...10 4 ...
Page 365: ...11 3 ...