150
...
...
..
..
Trouble shooting
7.1.2 H codes
H0
Wheel silent running cannot be improved with
balancing optimisation.
H1
Further optimisation is not recommended but is
possible.
H2
Weight minimisation is recommended, further
optimisation does not bring improvements.
H22
Pedal unclamping is disabled.
The machine is equipped with a clamping device
fi tted with a tie rod on the chuck (e.g. USV or SCA);
unintentional unclamping could damage the tie rod.
H26
The gauge was moved too quickly.
Return the gauge to the starting position and repeat
the operation, making the gauge approach the weight
application point more slowly.
E502
Laser Pointer failure
•
Contact technical service team.
E503
Laser Pointer failure
•
Contact technical service team.
E504
Laser Pointer failure
•
Contact technical service team.
E505
The Lifter does not respond to commands.
•
Contact technical service team.
E506
The rear scanner does not respond to commands.
•
Contact technical service team.
E900
Unknown machine model.
E901
The machine is not calibrated.