122
...
...
. .
...
...
.
...
...
. .
...
...
.
5-81
5-82
5-83
5-84
8
Operation
Message E9
Message
E9
means that at least one error has occurred
during the optimisation cycle (System messages
F
7.1).
—
Abort the optimisation program by pressing the
STOP
key and, if desired, start optimisation once
again.
Figure 5-81
OPTIMISATION “
12
”
(fourth measuring run with tyre)
—
Clamp the wheel.
—
Position the valve so that it is exactly perpendicular
to and above the chuck.
—
Confi rm the valve position by pressing key
8
.
The OPTIMISATION “13” screen appears (
Fig. 5-82
).
Figure 5-82
OPTIMISATION “
13
”
START is signalled on the screen
—
Perform the wheel measuring run.
A measuring run is performed.
The BALANCING screen appears (
Fig. 5-83
).
Finish weight Optimisation
Figure 5-83
BALANCING
—
Balance the wheel according to the readings.
Fig. 5-84
If the silent wheel running conditions are optimal, the
following codes can be displayed:
H0
Silent wheel running conditions cannot be
improved by optimisation.
H1
Further optimisation not recommended but possible.
H2
Weight minimisation is recommended, optimisation
can achieve no further improvement.
Summary of Contents for Geodyna 8250p
Page 176: ...176 Blank Page ...