52
Chapter 1 Error Codes
6005 8902
An error occurred during the port change.
Please call the Hitachi Data Systems Support
Center.
E 4
6005 8903
Unknown Error Code.
The Remote Console PC detected an unknown
error code. Please call the Hitachi Data Systems
Support Center.
E 4
6005 8904
The Remote Copy Function Switch bit No. 5 in MCU is
on, although the difference management areas in
MCU are full.
Check the difference management instruction for
other pair in MCU, and decide which instruction
the target pair chooses. After that, perform the
following. -When creating the target pair by the
track, create after recreating the other pair by the
cylinder. -When creating the target pair by the
cylinder, create by performing the difference
management instruction in cylinder, or turning off
the bit #5 of the switch for MCU remote copy
function.
E 5
6005 8905
The extended SM is not equipped in MCU.
Install SM to MCU with the installation instruction
of SM for remote copy extension (Install
TrueCopy Function).
E 5
6005 8906
The Remote Copy Function Switch bit No. 5 in MCU is
on, although the difference management areas in
RCU are full.
Check the difference management instruction for
other pair in RCU, and decide which instruction
the target pair chooses. After that, perform the
following. -When creating the target pair by the
track, create after recreating the other pair by the
cylinder. -When creating the target pair by the
cylinder, create by performing the difference
management instruction in cylinder, or turning off
the bit #5 of the switch for MCU remote copy
function.
E 5
6005 8907 The
extended SM is not equipped in RCU.
Install SM to RCU with the installation instruction
of SM for remote copy extension (Install
TrueCopy Function).
E 5
6005 8908
Invalid parameter.
Please check the value of the specified
parameter and retry.
I 4
6005 8909
A Port exchange error occurred.
The Remote Console PC detected a port
exchange error. Please contact the Hitachi Data
Systems Support Center.
E 4
6005 8910
A Port exchange error occurred.
The Remote Console PC detected a port
exchange error. Please contact the Hitachi Data
Systems Support Center.
E 4
6005 8911
Logical paths exist on the port.
The Remote Console PC detected a logical path
(S/390
®
) on the port. Please delete the path(s)
and retry the operation.
I 4
6005 8912
Logical paths exist on the port.
The Remote Console PC detected a logical path
(S/390
®
) on the port. Please delete the path(s)
and retry the operation.
I 4
6005 8913
Invalid port type.
Please check the port status and retry.
W
4
6005 8914
Multi platform feature already installed in subsystem. The multiplatform feature has already been
installed in the subsystem. Please verify the
configuration of the subsystem.
I 4
6005 8915
The port type exchange operation is rejected because
the host(s) is(are) processing the port type exchange.
Check the port status, and retry the operation
once the port type has been exchanged.
E 4
6005 8917
Too many pairs in this CTG.
Register a new CT group, and register the
ASYNC pair.
W 0