50
Chapter 1 Error Codes
6005 8859
Delete Pair(Pairsplit-S) operation with C/T option
failed because some R-VOLs in the group are in
Duplex(PAIR) or Pending(COPY) status.
Select [OK] to continue the operation without
shut down of the connected SCSI host(s). Select
[Cancel] if you need to terminate the operation
and shut down the host(s).
I 4
6005 8860
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8861
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8862
Please wait a few minutes and retry the Delete
Pair(Pairsplit-S) operation.
The delete pair (Pairsplit-S) operation failed. A
few minutes later, please refresh the screen,
confirm if the specified volumes are in the
permissible status, and then retry the operation.
I 4
6005 8863
Unknown Error Code.
The Remote Console PC detected an unknown
error code. Please call the Hitachi Data Systems
Support Center.
E 4
6005 8864
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8865
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8866
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8867
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8868
Duplicate CT Group#(A CT Group has been already
active in MCU).
The operation failed because a duplicate C/T
Group is already active in the MCU. Verify the
status of the C/T group and retry the operation.
E 4
6005 8869
CT Group is not active.
Verify that the C/T group is active in the MCU.
E
4
6005 8870
CT Group Option cannot be changed unless all
asynchronous pairs in the group are suspended or
deleted.
The group operation failed because the specified
group has at least one asynchronous pair.
Renew and check the TrueCopy screen.
I 4
6005 8871
The TrueCopy – S/390
®
Asynchronous function is not
installed in specified MCU.
Install TrueCopy Asynchronous in the MCU and
retry the operation.
I 4
6005 8872
This version does not support multi CT Groups in the
MCU.
This microcode version does not support multiple
C/T Groups in the MCU. Verify the status and
retry the operation.
I 4
6005 8873
TrueCopy Asynchronous function is not installed in
specified MCU.
Install the TrueCopy Asynchronous function in
the MCU, then retry the operation.
I 4
6005 8874
Invalid Timer Type option.
Specify "Local" or "None" for the timer type on
the TrueCopy panel, then retry the operation.
I 4
6005 8875
At least one asynchronous pair is active in this group. Renew and check the TrueCopy screen.
E
4
6005 8876
There are no PCBs which corresponds to the
specified port type.
Confirm the PCB type and try the operation again
with a correct parameter.
I 4
6005 8877
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8878
CT Group is not active.
Verify that the C/T group is active in the MCU.
E
4
6005 8879
At least one asynchronous pair is active in this group. Verify that there are no active asynchronous
pairs in this group, and retry the operation.
I 4