Hitachi Lightning 9900™ V Series Remote Console Error Codes
59
7010 8531
Internal logical error.
Contact Hitachi Data Systems Support Center. I
0
7010 8532
The P-VOL and S-VOL are being used from the host
or by Remote Copy.
Check the target volume, or stop using it in
Remote copy.
I 0
7010 8533
The emulation type of the specified reserved volume
is not supported.
Specify the volume of the supported emulation
type.
I 0
7010 8534
An internal logical contradiction occurred.
Contact Hitachi Data Systems Support Center. I
0
7010 8535
A processor failure was detected.
Contact Hitachi Data Systems Support Center. I
0
7010 8536
A cache failure was detected.
Contact Hitachi Data Systems Support Center. I
0
7010 8537
The cache capacities do not match.
Contact Hitachi Data Systems Support Center. I
0
7010 8538
An SM failure was detected.
Contact Hitachi Data Systems Support Center. I
0
7010 8539
There is insufficient shared memory to create 4096
pairs.
There is insufficient shared memory in DKC.
Contact Hitachi Data Systems Support Center.
I 0
7010 8540
There is sufficient shared memory to create 4096
pairs, but initial subsystem setup is required before
creating pairs.
Contact Hitachi Data Systems Support Center. I
0
7010 8541
There is sufficient shared memory to create 4096
pairs, and the initial subsystem setup is complete.
I
0
7010 8542
Failed to complete the initial shared memory setup.
Contact Hitachi Data Systems Support Center. I
0
7010 8543
The shared memory size is different.
Contact Hitachi Data Systems Support Center. I
0
7010 8544
16 Mbytes of shared memory are available.
I
0
7010 8545
A power supply failure is detected.
Contact Hitachi Data Systems Support Center. I
0
7010 8546
The command was rejected. The PS OFF is in
progress.
Retry the operation with power ON.
I
0
7010 8547
A data transfer failure is detected (CHA).
Contact Hitachi Data Systems Support Center. I
0
7010 8548
A data transfer failure is detected (DKA).
Contact Hitachi Data Systems Support Center. I
0
7010 8549
The P-VOL is not implemented.
You cannot execute the operation for the volume
which is not implemented.
I 0
7010 8550
The P-VOL cannot be used.
Contact Hitachi Data Systems Support Center,
and check if the volume status is normal.
I 0
7010 8551
The P-VOL is being formatted.
Wait until the volume is formatted, and retry the
operation.
I 0
7010 8552
The P-VOL is a command device.
Check the target volume.
I
0
7010 8553
The S-VOL is not implemented.
You cannot execute the operation for the volume
which is not implemented.
I 0
7010 8554
The S-VOL cannot be used.
Contact Hitachi Data Systems Support Center,
and check if the volume status is normal.
I 0
7010 8555
The S-VOL is being formatted.
Wait until the volume is formatted, and retry the
operation.
I 0
7010 8556
The S-VOL is a command device.
Check the target volume.
I
0
7010 8557
The volume is not implemented.
You cannot execute the operation for the volume
which is not implemented.
I 0