Hitachi Lightning 9900™ V Series Remote Console Error Codes
29
3010 9102
Do you want to apply?
To execute the operation in Preset, press the OK
button.
I 0
3010 9103
Do you want to change?
I
0
3010 9150
Specify the SSID.
I
0
4010 1030
Part of the range is already in use.
Correct the specified content, and issue the
request again.
I 0
4010 1032
The specified value is outside the valid range.
Correct the specified content, and issue the
request again.
I 0
4010 2080
Prestaging not completed.
Wait for a while, and press the Refresh button,
and then change the same configuration again.
Or check the DKC status (if it is not blocked). If
the same error occurs, call the service personnel.
E 6
4010 5010
The specified value is invalid for FlashAccess area.
The value should be From<To.
Correct the specified content, and retry.
W
5
4010 5011
The specified value is under one cylinder.
Correct the specified content, and retry.
W
5
4010 5030
No deletion area is specified. Retry the operation to
specify the deletion area.
Correct the specified content, and retry.
W
5
4010 7060
An error occurred in the Client logic.
Call the service personnel.
E
2
4010 9000
Prestaging is completed.
I
0
4010 9010
The system will set the contents.
I
0
4010 9060
Do you want to delete?
I
0
5105 2002
An error occurred. If this problem persists, please call
the Support Center.
The size of a CV which links as an expanded LU
is not the same. Or you are trying to link CV and
normal volume. The error does not occur
normally because it is guarded in the screen.
Contact the program maker.
E 2
5105 2015
A connection error has occurred.
Retry the same operation. If the same error
occurs despite retrying, call the service
personnel.
E 4
5105 2145
A connection error has occurred.
Retry the same operation. If the same error
occurs despite retrying, call the service
personnel.
E 4
5105 5010
An error occurred. If this problem persists, please call
the Support Center.
WWN number, which is not registered, is
specified. (When deleting, or changing) The
error does not occur normally because it is
guarded in the screen. Contact the program
maker.
E 2
5105 5013
An error occurred. If this problem persists, please call
the Support Center.
You are trying to perform Virtual LVI/LUN
operation for a volume which LU path is set, LU
expanded volume, or a volume which LDEV
Security is set. The error does not occur normally
because it is guarded in the screen. Contact the
program maker.
E 2
5105 5099
An error occurred. If this problem persists, please call
the Support Center.
You are trying to register the same host group
number as the existing number. The error does
not occur normally because it is guarded in the
screen. Contact the program maker.
E 2
Summary of Contents for Freedom Storage Lightning 9900 V series
Page 1: ...Hitachi Freedom Storage Lightning 9900 V Series Remote Console Error Codes ...
Page 2: ......
Page 6: ...vi Preface ...