64
Chapter 1 Error Codes
7010 8659
There is no Fibre-Channel port.
E
5
7010 8920
Because a L1 pair is not PSUS, you cannot operate to
L2.
Wait until L1 pair becomes PSUS status, and
execute the operation to L2 pair.
I 0
7010 9002
Normal end.
The operation was ended normally. Execute the
next operation.
I 0
7010 9005
An error occurred. Check the error code.
An error occurred during the indicated operation.
Refer to the error code for each operation in
Preset Volume List.
I 0
7010 9101
Do you want to cancel?
To cancel, press the OK button.
I
0
7010 9102
Do you want to apply?
To execute the operation in Preset, press the OK
button.
I 0
7010 9108
The option has been changed. If you continue
processing before applying the change, the option will
be reset to the current setting. Do you want to
continue processing?
W
0
7010 9109
Do you want to execute the Set Over operation?
W
2
7010 9110
Do you want to execute the Initialize operation?
To execute the Initialize transaction, press the
OK button. (Inserted only in M.M)
W 2
7105 5099
An error occurred. If this problem persists, please call
the Support Center.
You are trying to set SubSystem ID without
Virtual LVI/LUN operation. The error does not
occur normally because it is guarded in the
screen. Contact the program maker.
E 2
7110 5115
The T-VOL size differs from the specified source
volume size.
Check the capacity of S-VOL and T-VOL. Specify
a volume with the same capacity, and retry the
operation.
W 0
7110 5116
You cannot create another pair, because the number
of pairs exceeds the maximum.
You cannot create the specified pair. Delete the
created pair, and then retry the operation.
W 0
7110 5119
The S-VOL is not selected
Select the S-VOL, and retry the operation.
W
0
7110 5120
The T-VOL is not selected.
Select the T-VOL, and retry the operation.
W
0
7110 5121
The data has been changed. If you select another tab
(page), the settings will be discarded. Are you sure
you want to change the pages?
Apply the data in the Preset Volume List. To stop
the transaction, press the OK button and
continue the operation.
W 0
7110 5122
No data has been changed.
Go on to the next operation.
W
0
7110 5123
The password is invalid.
Check the password.
W
0
7110 5124
You cannot select more than one operation at a time. Multiple volumes cannot be processed in the
operation. Process one volume at a time.
W 0
7110 5125
No target volume is selected.
Select the target volume.
W
0
7110 6502
Currently processing. Wait a few minutes and then
retry the operation.
Wait for a while, and retry the operation.
I
0
7110 6503
The volume status is being changed to simplex.
Wait for a while, and retry the operation.
I
0
7110 6504
The number of pairs exceeds the maximum.
You cannot create a pair for the specified S-VOL.
Delete the created pair, and retry the operation.
I 0
7110 7310
Unregistered error code.
Contact Hitachi Data Systems Support Center. W
0