Hitachi Lightning 9900™ V Series Remote Console Error Codes
33
5205 1246
The number of plan that could be executed at once is
exceeds the maximum.
Retry the same operation. If nothing changes,
contact the service personnel.
E 6
5205 1247
The specified volume is already a source volume.
Retry the same operation. If nothing changes,
contact the service personnel.
E 5
5205 1606
The option product (CruiseControl) is not installed.
Install the necessary program product.
E
5
5205 2003
An internal process is being executed, or maintenance
is in progress. Please try again.
Confirm that maintenance operation is not in
progress, and retry after a while.
E 5
5205 2004
An error occurred. If this problem persists, please call
the Support Center.
The specified emulation type of CV cannot
coexist. The error does not occur normally
because it is guarded in the screen. Contact the
program maker.
E 2
5205 2011
The controller is busy now. Please retry a little later.
E
5
5205 2024
The controller detected the blockade location.
Call the service personnel.
E
4
5205 2025
The controller detected the blockade location.
Call the service personnel.
E
4
5205 2026
The controller detected the blockade location.
Call the service personnel.
E
4
5205 2027
The controller detected the blockade location.
Call the service personnel.
E
4
5205 2028
The controller detected the blockade location.
Call the service personnel.
E
4
5205 2029
A data transfer failure was detected.
Call the service personnel.
E
4
5205 2030
A data transfer failure was detected.
Call the service personnel.
E
4
5205 2033
The server is now gathering the latest data. Internal
processing is being executed. Please wait a while,
and then click the Refresh button.
Wait for a while, and press the Refresh button.
W
4
5205 3002
An error occurred. If this problem persists, please call
the Support Center.
When Virtual LVI/LUN operation (Volume
Initialize) is performed, the number of volumes
which should be returned to Normal Volume and
the number of volumes which is requested in
Volume Initialize are different. The error does not
occur normally because it is guarded in the
screen. Contact the program maker.
E 2
5205 3003
An error occurred. If this problem persists, please call
the Support Center.
When Install CV was set, the emulation type and
the specified size of the emulation type were
specified incorrectly. (User specified capacity is
specified to mainframe volume. The user
specified number of cylinders is specified to open
volume.) The error does not occur normally
because it is guarded in the screen. Contact the
program maker.
E 2
5205 5013
An error occurred. If this problem persists, please call
the Support Center.
You are trying to perform LUN Security operation
for a port where LUN Security function is invalid.
The error does not occur normally because it is
guarded in the screen. Contact the program
maker.
E 2
5205 5099
An error occurred. If this problem persists, please call
the Support Center.
You are trying to set an expanded LU which
includes an already expanded LU. The error
does not occur normally because it is guarded in
the screen. Contact the program maker.
E 2
5205 6000
An error occurred. If this problem persists, please call
the Support Center.
If the same error occurs despite retrying, call the
service personnel.
E 2