40
Chapter 1 Error Codes
6005 8714 An
internal
error
occurred.
The command to delete the RCU is rejected
because there is at least one pair established in
the RCU. Delete the pair(s) that apply to that
RCU and then retry the delete RCU operation.
E 4
6005 8715
Invalid number of paths.
The specified number of paths is not within the
acceptable path range of 0 to 4. Please verify the
number of paths and retry the operation.
E 4
6005 8716
Specified port is not RCP.
Check the configuration of the LCP/RCP, then
either specify the correct port or change the port
to RCP.
E 4
6005 8717
Invalid Destination Link Address.
The specified logical address must be either 00
or 01. Check the logical address and retry the
operation.
E 4
6005 8718
The specified logical path already exists.
The specified link address and port are already in
use. Check all existing logical path addresses,
and specify another link address or RCP port.
I 4
6005 8719
Invalid RCU serial number, SSID, Link Address or
Controller ID.
Check the serial number, SSID and link address
of the RCU, and set the correct value. Then retry
the operation. If the same error occurs, contact
the Hitachi Data Systems Support Center.
E 4
6005 8720
Too many RCUs. (Four RCUs allowed).
A maximum of four RCUs are permitted, and that
many already exist.
I 4
6005 8721
Path establishing is not complete.
Check the path connections between the MCU
and the RCU, then retry the operation.
E 4
6005 8722
Path establishing failed.
Check the path connections between the MCU
and the RCU, then retry the operation.
E 4
6005 8723
The Edit Path operation was rejected because the
specified path is the last path of some Remote Copy
pairs.
Add another path, or delete all pairs on the RCU.
Then retry the operation.
I 4
6005 8724
Specified number of Path is less than the Minimum
Paths on RCU Option screen.
The specified number of paths is less than the
minimum number of paths specified on the RCU
Option panel.
I 4
6005 8725
Currently running microprogram version does not
support the specified operation.
The 9900V microcode version does not support
the specified function or operation. Please
contact the Hitachi Data Systems Support
Center.
I 4
6005 8726
Multi platform feature already installed in MCU.
The multiplatform feature has already been
installed in the MCU. Please verify the
configuration of the MCU.
I 4
6005 8727
The number of minimum paths is more than the
number of normal paths.
If the error code is 100c, please set the minimum
number of paths after adding the normal path(s).
If the error code is 400c, please delete the paths
after adding them, or delete the paths after
decreasing the number of minimum paths.
I 4
6005 8728
The number of minimum paths is more than the
number of normal paths.
If the error code is 100c, please set the minimum
number of paths after adding the normal path(s).
If the error code is 400c, please delete the paths
after adding them, or delete the paths after
decreasing the number of minimum paths.
I 4
6005 8729
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4