background image

F2000 GETTING STARTED GUIDE

The F2000 is an ultra-fast, highly available storage array for editing, rendering, and processing of video content and other 

large unstructured data sets in a StorNext shared storage environment. 
This guide provides an introduction to the F2000 hardware and provides a high-level overview of the F2000 installation 

and configuration process. For complete documentation, refer to the 

F2000 Documentation Center

at 

www.quantum.com/F2000docs

In the 

F2000 Documentation Center

, go to 

Resources > F2000 Documentation Center 

Downloads 

if you need to download a local offline version of the documentation center

Activate your warranty and register your product with Quantum

: 

www.quantum.com/startup

F2000 Installation and Configuration

1 – Install the F2000 Hardware

Safety, prerequisites and requirements

Step 1: Choose an installation location

Step 2: Unpack the F2000

Step 3: Install the F2000 into a rack

Step 4: Cable the F2000

Connect Ethernet cables to the customer-

provided network switch

Connect FC or Ethernet model cables

Connect the power cables

Page 1

The F2000 installation process consists of installing the hardware and configuring the system. An overview of the steps 

starts below and continues on page 2. Use this overview as a checklist as you complete the installation. For detailed, 

step-by-step installation instructions, refer to the 

Install

menu on the 

F2000 Documentation Center 

or go directly to 

www.quantum.com/F2000Install

.

Drive bay includes 24 x Non-Volatile Memory 

Express (NVMe) Solid State Drives (SSDs)

Pull-out Tab with

System Serial Number

2000 W 

PSU A

2000 W 

PSU B

Controller B

Controller A

To Primary AC

Power Source

To Secondary 

AC Power Source

Port 1: to 1 GbE/10 GbE 

Network Switch

Port 1: to 1 GbE/10 GbE 

Network Switch

Port 4: 10 GbE Controller-to-Controller 

Connection (Pre-installed)

FC Model: 

A dual-port 32 Gb FC card is installed in 

PCIe Slot 1

and 

PCIe Slot 

3

in both controllers. Connect up to eight FC cables to the cards. At a 

minimum, one FC cable must be connected to Controller A and one FC 

cable must be connected to Controller B for the system to function 

properly. Then connect the other end of the cables to a 32 Gb FC switch. 

Ethernet Model: 

A dual-port 100 GbE card is installed in 

PCIe Slot 1 

in both 

controllers. For a 

single-subnet

configuration, connect one cable to 

Controller A and one cable to Controller B. For a 

dual-subnet 

configuration, 

connect two cables to Controller A and two cables to Controller B. Then 

connect the other end of the cables to a 100 GbE network switch. 

PCIe Slot 1

PCIe Slot 2

PCIe Slot 3

PCIe Slot 1

PCIe Slot 2

PCIe Slot 3

Before starting the installation, review the important safety information in the 

Install >  – Install the F2000 

Hardware > 

Safety, prerequisites and requirements

section of the 

F2000 Documentation Center. 

Port 4: 10 GbE Controller-to-Controller 

Connection (Pre-installed)

Controller A

Controller B

F2000 Hardware Overview

Fr

on

t

Re

ar

Drive Slot Numbering

(Example below shows controllers A and B with dual-port 32 GB FC 

cards in PCIe slots 1 and 3. Dual-port 100 GbE cards are also available.)

IPMI/BMC Port

IPMI/BMC Port

Reviews: