Chapter IV Function Parameter Table
88
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value
Change
Fb.08
Reserved -
-
-
*
Fb.09
The local
IP address
is 1
segment
Set range
:
0
~
255
Set the local IP address for Ethernet
communication.
Local IP address format
:
Fb.09.Fb.10.Fb.11.Fb.12
。
For example, the local IP address is
192.168.1.30.
1
192
○
Fb.10
The local
IP address
is 2
segment
1
168
○
Fb.11
The local
IP address
is 3
segment
1
1
○
Fb.12
The local
IP address
is 4
segment
1
30
○
Fb.13
Subnet
mask 1
segment
Set range
:
0
~
255
Set the subnet mask for Ethernet
communication.
Subnet mask format:
Fb.13.Fb.14.Fb.15.Fb.16
。
For example, the subnet mask is
255.255.255.0.
1
255
○
Fb.14
Subnet
mask 2
segment
1
255
○
Fb.15
Subnet
mask 3
segment
1
255
○
Fb.16
Subnet
mask 4
segment
1
0
○
Fb.17
Gateway 1
section
Set range
:
0
~
255
Set the gateway for Ethernet
communication.
The gateway format
:
Fb.17.Fb.18.Fb.19.Fb.20
。
For example, the gateway is 192.168.1.1.
1
192
○
Fb.18
Gateway 2
section
1
168
○
Fb.19
Gateway 3
section
1
1
○
Fb.20
Gateway 4
section
1
1
○
Group FC: Auxiliary function parameters
FC.00
Energy
consumpti
on braking
threshold
FC.00 set range: 350
~
800V
FC.01 set range: 0
~
100%
1. Energy consumption braking function.
If the drive bus voltage is higher than the
energy consumption braking threshold,
the built-in braking unit will act. In this
case, if a braking resistor is connected, the
pumping voltage energy at the drive
internal current side will be released
1V
Model
determina
tion
×
FC.01
Energy
consumpti
on braking
duty cycle
1%
50%
×