Chapter IV Function Parameter Table
43
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value
Change
to change this parameter.
F1.26
Overmodu
lation
factor
Setting range: 100
~
150%
This function enables PWM to work when
the modulation ratio is greater than 1,
which can increase the output voltage of
the drive. Thereby increasing the torque
output and effectively improving the
maximum load capacity of the motor but
the harmonic components of the output
voltage will increase and cause the
temperature of the motor to rise.
1%
110%
×
F1.27
Automatic
carrier
frequency
adjustment
0: disable
1: enable
When the automatic adjustment of the
carrier frequency is enabled, the drive will
automatically adjust the carrier frequency
according to the temperature.
1
0
○
F2 group: Start-stop control
F2.00
Start
operation
mode
LED single digit: Start mode
0: Start from the start frequency:
Start at the start frequency set by
F2.01, and accelerate to the set
frequency after running the hold
time set by F2.02 at this
frequency.
1: Brake first and then start from the
start frequency: First start with
the DC braking current set in
F2.03 and the DC braking time
11
00
×