Chapter IV Function Parameter Table
66
Parameter
Code
Parameter
name
Parameter detailed description
Minimum
Unit
Factory
value
Change
negative (connected with the common
terminal is invalid, disconnected is valid).
F6.25
DI polarity
switch 2
00000
~
11111
LED unit digit: DI6 polarity (expansion
card)
LED tenth digit: DI7 polarity (expansion
card)
LED hundredth digit: DI8 polarity
(expansion card)
LED thousandth digit: reserved
LED ten thousandth digit: reserved
This function code is used to set the
polarity of the digital input. When the bit
is set to 1, the input polarity is positive
(connected to the common terminal is
valid and disconnected is invalid). When
the bit is set to 0, the input polarity is
negative (connected with the common
terminal is invalid, disconnected is valid).
11111
11111
○
F6.26
DO output
switch
polarity 1
00000~11111
LED single digit: DO1 positive/negative
logic definition
LED tens digit: DO2 positive/negative
logic definition
LED hundreds digit: Relay
positive/negative logic definition
LED thousands digit: Reserved
LED 10 thousands digit: Reserved
This function code is used to set the
polarity of the output switch. When the bit
is set to 1, the output switch is positive
logic, when the bit is set to 0, the output
switch is negative logic.
11111
11111
○
F6.27
Reserved -
-
-
*
F6.28
DI filter
time
0
~
1000ms
Set DI1
~
DI5 common terminal function
input filter time. In the case of large
interference, you shall increase the set
value of this function code to prevent
mis-operation.
1ms
5ms
○
F6.29
DO1
output on
delay
Set range: 0.0
~
600.0s
This function code defines the delay from
the status change of the switch output
terminal and the relay to the output
change.
0.1s
0.0s
○
F6.30
DO1
output off
delay
0.1s
0.0s
○
F6.31
DO2
output on
delay
0.1s
0.0s
○
F6.32
DO2
0.1s
0.0s
○