C H A P T E R 4 :
T H E E N G I N E E R F U N C T I O N S
Please note that any programming done in the Engineers Menu will not be seen by the system
until you have exited and the system has saved its data (please see Page: 5).
Clean Start
It is essential that the Non-Volatile Memory (NVM) be reset at initial power up of a new
system, to ensure that the initialisation is correct to factory defaults.
The ‘CLEAN START’ function will clear all information apart from the user codes and the logs.
After the system has completed a reset, it will prompt with ‘
Clear Codes?
’ If ‘Yes’ is selected
then all user codes will be cleared. Once this has completed, the system will then prompt
‘
Clear Logs
’. If ‘Yes’ is selected, all the logs will be cleared. The process below describes how
to do this.
The system memory will now be restored to factory defaults EXCEPT:
Keypad 00 remains enabled at all times & the keypad in use remains enabled
Current keypad Areas are not changed
It is also possible to perform two different clean starts.
Grade 2 default clean start -
2002
Grade 3 default clean start
-
2000
Using the
and
keys, scroll to
‘
CLEAN START?
’
Press the
key.
The following will be displayed:
Enter chosen clean start code
“
Please Wait
” will be displayed, and
then ‘Panel has been clean started’.
Press the
key.
“Clear Codes”
will be displayed”. If you would like to
clear all the codes then press the
key now. “Codes have been cleared”
will be displayed. Otherwise press the
key.
“
Clear Logs
” will be displayed.
If you would like to clear the logs then
press the
key now. “Logs have
been cleared” will be displayed.
Otherwise press the
key. You will
be returned to the Engineer Menu.