Engineer Reset Options
The Engineer Reset Options are used so that once an alarm has occurred; the system can only
be reset by an engineer code, anti-code or red care reset from the alarm-receiving centre.
Option
Function
Engineer
Restore of
Intruder
Following an intruder alarm, an engineer must reset the system before it
can be used again. Please select ‘UK Intruder’ to enable this, ‘Secure
Intruder’ should not be used. This will not interfere with the generation of
an emergency alarm.
Default = No.
Engineer
Restore of HU
Following a Hold Up, Input HU or Duress alarm, an engineer must reset
the system before it can be used again. This will not interfere with the
generation of a Fire or Gas (emergency) alarm.
Default = No.
Engineer
Restore of
Tamper
Following a Tamper alarm, an engineer must reset the system before it
can be used again. This will not interfere with the generation of an
emergency alarm.
Default = Yes.
Engineer
Restore of
Soak
In the event of an input with the ‘soak’, attribute triggering whilst the
system is set, the system must be reset by an engineer before it can be
used again. This will not interfere with the generation of an emergency
alarm.
Default = No.
Engineer
Restore of
Confirmed
Following a confirmed alarm, an engineer must reset the system before it
can be used again.
Default = Yes.
Engineer
Restore of
Faults
If selected, only an Engineer’s code will be able to reset the following
faults: ATE telecom fail, Modem fail, ATE single path fail, Telecom line fail,
Battery disconnect, Batt charge, Batt load, Excessive charge, Battery
critical, Device fail.
Default = No.
Anti-Code
Restore
Enables the system to display an anti-code whilst awaiting an Engineer
reset, which can be used to generate a special reset code.
Default = No.
Engineer Restore Options
Using the
and
keys, scroll to
‘ENGINEER RESTORE OPTIONS?
’
Press the
key
Eng Restore Int
Enter
: for
No
Enter
: for
UK Intruder
Press the
key.
Repeat the above options for the
restores: Tamper, Soak, Confirmed,
and Faults
(Enter
: for
No,
: for
Yes
)
Press the
key.
Anti-Code Restore
Enter
: for
No
Enter
: for
Yes
Please note that if Anti-Code is
selected, this will coincide with the
options you have selected previously.
For example, if ‘Engineer Restore
Intruder’ is selected, and Anti-Code is
selected, then an anti-code will be
produced on an Intruder activation.