Page | 49
The log will be displayed. Use the
and
keys to scroll through
the log.
For more information on an event
(such as alarm silenced for
example), press the
key.
Press the
key to exit.
Access Log
Repeat the above for the Access log.
When you wish to exit, press the
key. You will be returned to the
Engineer Menu.
Engineer Tests
The Test function allows the engineer to test inputs, outputs, batteries and the siren.
4.1.50 Sounds To Play
This function allows you to listen to the different tones that the system makes. E.g. Chime
Single, Chime Follow, Exit, Exit Fault, Entry, Tech Fault, Tamper, Alarm, HU, and Fire.
4.1.51 Walk Test
Please note that the walk test feature can only be used when engineer mode is exited after the
programming of inputs.
This function allows the engineer to test all programmed inputs on the system. The inputs that
haven’t been activated will be shown on the display. Once all the inputs have been walk
tested, ‘Walk Test Completed’ will be displayed.
When walk-testing a double-knock detector, it must be triggered twice within the pre-set
period. When testing dual-trip detectors you must first open detector one and then trigger the
second detector; next open the second detector and trigger the first detector.
4.1.52 Soak Control
Any input may be placed on ‘soak test’ to prevent it from generating an alarm. If the input
triggers whilst the system is set, it will indicate the activation and enter the details in the
system log. You can also enter the number of days you would like the soak test to last, after
this period the inputs will be active.
4.1.53 Test Siren
Any outputs programmed with a siren or strobe configuration will be activated.
4.1.54 Do Battery Load Test
Battery Test
The system performs a check of the battery operation every 10 seconds, by dipping the power
supply voltage momentarily, and measuring the system voltage. If the battery voltage
measured is below 12.0V, or the battery fuse has failed, a ‘BATTERY FAULT 100’ warning will
be generated.