Page | 51
be tested. To remove an input from the
list, enter its number again. Press
Soak Days Left
Enter the number of days the soak test
will last. Press the
key.
Initial
Soak:
Enter the number of days the
soak test will revert to in the event a
soak input is triggered during testing.
This is recommended to be greater
than or equal to “Soak Days Left.”
Press the
key. ‘Soak Control’ will
be displayed, press the
key.
Test Siren?
To Test the Siren press the
key. All
outputs programmed as either Siren, or
Strobe will be tested. ‘Testing Siren’
will be displayed. Press the
key to
stop the test. ‘Test Siren’ will be
displayed, press the
key.
Do Battery Load Test?
To perform a Battery Load Test, press
the
key. The Battery Load test will
be started. Once the Battery test has
completed, the LCD will display
whether the battery has ‘passed’ or
‘failed’ press the
key, ‘Do Battery
Load Test’ will be displayed, press the
key.
Test Outputs?
This tests all the outputs on the control
panel (including outputs on ZEMs,
Output Modules, and ATE pins) To test
the outputs press the
key. Select
the Output type you would like to test
(see page 38 for the output types) and
press the
key.
All outputs programmed as the type
selected will be active. Press the
key. The outputs will switch off. Repeat
for other output types as required.
Press the
key. ‘Test outputs’ will be
displayed. Press the
key. You will
be returned to the Engineer Menu.
Test Communications?
If you would like to test SIA or Contact
ID communications, press
’Are You
Sure?’ will be displayed. Press
again and a test signal will be sent to
the ARC. Press