Page | 35
Volume Control
The Volume Control function applies to the loudspeaker output only. Volume levels at the
keypad are programmed individually – please see page: 6.
4.1.34 Code Stops Sound
If this function is enabled, then once an alarm has been generated (even if the code is not
programmed for that area) the alarm will be silenced, and a ‘Misoperation (Abort) signal’ will
be sent, but the area will still be set until a valid user that controls that Area is entered.
The default is ‘Yes’.
If disabled, the codes will only work for the programmed area.
4.1.35 E / E Keypads Only
If there is a speaker connected to the SPK output of the EURO system the entry and exit tones
will be heard through the speaker. If you would like Entry and Exit tones to be heard on only
the keypad and not the speaker then enable this function.
The default is selected as ‘No’.
4.1.36 Alert Kps Only
If this function is enabled then any Alert tones will be heard on the Keypad only and not the
panel speaker.
The default is selected as ‘Yes’.
4.1.37 Silent Technical Alert
If this function is enabled then any technical alerts will be silenced.
The default is selected as ‘No’.
4.1.38 Volume Control Menu
Note: 0=Completely Silent, 1=Silent, but sounds a beep when the system is set.
7=Maximum Volume
The default volume settings are as follows:
Entry:
4
Tamper
6
Exit
4
Day Alarm
6
Alarm
7
Chime
3
Fire
7
Intelligent Set
3
Volume Control
Using the
and
keys, scroll to
‘VOLUME CONTROL?
’
Press the
key
Area Volume
Use the numeric keys select the volume
level required for Entry and Exit tones
for each Area, once selected, press the
key.
Repeat for Alarm, Fire, Tamper, Day
Alarm, Chime and Intelligent Set tones.
Press
Code Stops Sound
Enter
: for
No
Enter
: for
Yes
Press the
key. Repeat for E/E
Keypads Only, Alert Keypads Only, and
Silent Technical Alert.
Press the
key. You will be returned
to the Engineer Menu