Page | 6
Number of Areas/Level Sets
Euro 280:
14 level sets/areas
Initial Power Up
When powering up the Euro 280 system on
mains only
, an alarm will be generated. Proceed
to keypad addressed as 00, which will display (from power up):
The following will be displayed:
When the display shows: ‘Battery
Fault’ and
NOT
before, connect the
battery to the panel.
In the keypad function, there are also other individual options such as: language, the status of
the keypad inputs, key-click volume, tag volume, master volume and the tag iD.
The tag iD is used to show the identification code for each proximity tag.
The Addressing Keypads Function
To address further keypads on the Euro 280 system, press and hold the
key until
“
SECURITY CODE
” is displayed. Then enter ‘2000’ as the code. This will take you to the
screens above. Once this has been done you will need to assign the keypad in engineers mode,
see ‘Assign Keypads/Readers’ on page: 23. Note: To address the readers you must select the
relevant switches on the circuit board, see the installation manual for more information.
Any keypad that is not correctly assigned will have a blank display until they are addressed.
Testing the Keypad
With the system unset, press the
key for 10 seconds at any keypad. This will cause all the
LEDs on that keypad to illuminate, and the LCD screen to scroll a display testing each pixel.
The keypad will revert to normal display approximately 10 seconds after the key is released.