Page | 53
The status of wired and wireless
ZEM inputs will also be shown in
the below format.
C
= Closed.
O
= Open.
F
= Fault
T = Tamper* B = Battery*
S = Supervision*
*Wireless inputs only
Press the
key again to view
the resistance readings.
The circuit resistance will be
shown on any of the inputs you
choose (enter the input number).
This is only applicable for wired
inputs.
>25.0k
: Open Circuit
<0.01k
: Short Circuit
Press the
key and you may
view the same for each ZEM,
Keypad or Reader. You will then
be sent back to ‘View Inputs’.
View Wireless Device Status
To view the wireless device
status for each wireless
peripheral installed.
Signal Strength
Press the
key to view the
signal strength of the wireless
devices.
Inputs
Press the
key to view the
inputs or press
for to view
the bells.
Wireless ZEM Address
Use the
and
keys to
select the wireless ZEM address
(each contains 8 wireless inputs)
and press
.
‘Please wait’ will be displayed
while the system gathers the
wireless information. Press the
key to exit this display.