Set / Unset System
If you do not have access to a user code, setting and unsetting the system can be done using
the engineer’s code.
Enter Engineer Code (default
1111).
“
SET / UNSET SYSTEM
?” will
be displayed
Press the
key
Select the Area(s) you would like
to set. Press the
key. The
system then will begin to set. To
unset the areas, enter the
engineer code, and wait a couple
of seconds. ‘
SET / UNSET
SYSTEM’
will be displayed, press
the
key. To unset the areas,
press the
key.
NOTE: If the system has been set by any other code, the Engineer code will not unset
it.
Forced Arm on Inputs
The ‘Forced Arm On Inputs’ allows the Engineer to set the system using the Engineer Code,
forcing it to Set despite inputs in fault condition, and nominate which inputs must be triggered
to generate an alarm condition. This is a useful feature if you need to test a system in a
building where people are walking around.
NOTE 1: The system will give the correct
DigiCom response to the Setting, and any resulting alarm.
On unsetting the system
(With the Engineer code or the User code), the system will revert to normal mode.
Enter Engineer Code (default
1111).
Any active faults will be
displayed, press the
key.
Press the
key again.
‘
FORCE ARM ON 1
st
INPUT?
’
will be displayed
Select the first input to be
forced armed and press the
key.
Select the second input to be
forced armed and press the
key.
Select the area(s) / level set you
would like to set. Press the
key. The system then will begin to
set.
When the input is triggered, the
alarm will be activated.
Please note the primary Areas are
A,B,C and D.