Page | 5
Entering the Engineers Menu
NOTE: You will not be able to access Engineers Mode if Areas or Set levels are set. The
system must be fully unset in order to gain access to the Engineer Menu. Access may
also be denied if the user has disabled the “Allow Engineer Menu” in the Master
Manager Menu. ‘Authorisation Required’ will be shown in this scenario.
Enter Engineer Code (default
1111).
Any active faults will be
shown. Press the
key.
“
SET / UNSET SYSTEM
?” will
be displayed.
Press the
key.
“
FORCE ARM ON 1
st
INPUT
[01]
” will be displayed.
Press the
key.
“
INHIBIT FIRE / HU?
” will
be displayed
Once you are in the Engineer Menu, a high pitch tone will be generated regularly to remind you
that you are still in the Engineer Menu.
Exiting the Engineer Menu
On completion of programming, the system can be returned back to normal mode by:
METHOD ONE
Use the scroll keys:
and
to scroll to “
EXIT
ENGINEERS MENU
”
Press the
key.
You will be returned to day mode
METHOD TWO
When the display shows any
main menu item (i.e. an item
shown in capitals) press the
key, you will be returned to day
mode.
Please see page: 68, for all fault codes that may appear when exiting Engineers.
C H A P T E R 3 :
P O W E R I N G U P & K E Y P A D O P E R A T I O N S
Before using the system, all items connected to the RS-485 communications bus must be
allocated a unique address.
Default Codes / Number of Areas/Level Sets
User:
1234
Master
Manager:
2222
Engineers
: 1111