Page | 38
Change Outputs
Any output type may be programmed to any of the systems outputs, including any outputs for
wireless bells. Outputs must be used within their rated capacity. Please see the installation
manual.
NOTE: Only the ATE outputs can be inverted.
4.1.42 Output Types
Type Active
Restore
0000 Not
Used
(permanently off)
0001 Fire
At alarm
When a valid code is entered
0002 Hold Up Any
At a HU or Duress alarm
(This includes keypad HU)
When a valid code is entered
0003 Intruder
Any
At alarm, while system is armed
At first valid code entry and at
end of confirm time.
0004 Final Set All
When system is FULLY armed
At code entry to unset
0005
Misoperation
(Abort)
When system is silenced after any
‘intruder’ output is triggered
After 2 minutes
0006 Confirmed
Any
When further input active in any
area after ‘intruder’ alarm or hold up At next code entry
0007 Tamper
Any
Any tamper alarm
At code entry to silence
And at end of confirm time.
0008 Duress
Any
At a Duress alarm (i.e. from a
keypad)
When a valid code is entered
0009 HU Device Any
At alarm on a HU input only
When a valid code is entered
0010 Gas
At alarm
When a valid code is entered
0011 Set
Fail
Pre-set time after start of exit time,
if exit procedure is not complete
At code entry to rearm
0012
Entry
Deviation
When deviation from entry route
occurs, during entry time
At code entry to unset
0013 Secure
Intruder Any
At alarm, after exit time started,
until unset
At first valid code entry and at
end of confirm time.
0014 Siren
Any
When alarm live
When alarm silenced or when
siren timer expires
0016 Strobe
Any
When alarm live
When alarm silenced or when
strobe timer expires
0017
Omit Rearm
Any
Input omitted if active (or in alarm
condition) at the end of confirmation
time.
When system disarmed
0018 Unconfirmed
Any
Any intruder alarm
At code entry to silence
0019 Can Set All
If all inputs and technical faults in
system are clear. Also once entry
time has started
If fault exists, and after final set
0020 Exit Starts All
At start of exit time to set LAST area
At code entry to unset FIRST
area
0021 Exit Starts Any
When exit time starts to set FIRST
area
At code entry to unset LAST
area
0022 Final Set Any
When FIRST area is set
At code entry to unset LAST
area
0023 Strobe
Set
Fail
Works similar to output 016, but also fires if the set fail timer expires.
0025
Keyswitch
unset
This output turns on for 5 seconds when the system is disarmed via a
keyswitch input (pulsed or latched)
0026 Set with Omit
Activates when inputs are omitted on setting
0028 Power
Fault
Active during low volts and battery faults
*
. Restores at code entry after
fault cleared.
0029
Confirmed
Intruder Any
When more than one intruder
alarm activates
At next code entry
0030
Confirmed
Hold Up Any
When more than one confirmed
hold up activates
At next code entry