Page | 39
Type Active
Restore
0031 Entry
Live during any entry time
0032 Exit
Live during any exit time
0033 Entry/Exit
Live during any entry or exit time
0034 Lights
When exit or entry timer starts
20 seconds after set/unset
procedure completed
0035
Follow Input
See page: 43.
When input triggers
Dependent upon programming
0036 Shunt
Fault
See Shunt Inputs - Page: 21
0037 Restore
1
At code entry to set
After 3 seconds
0038 Restore
2
At code entry to set
When unset
Re-triggers whenever an additional area is set
0039 PIR
Latch
1
When set (and in Walk Test)
At alarm, or when unset
0040 PIR
Latch
2
This is the inverse polarity to PIR Latch 1
0041 Mains
Good
Output showing the mains is healthy
0042
Detr Indn
Enable
This output activates during walk test and also when a code is entered
to view indications – staying activated for the time for which the
indications are viewed.
0043 Follow
Test
New output for alternative bell test by activating SAB
0044 Off During Test
New output for alternative bell test by activating SAB
0048 Detr
Walk
Test
This output is active during walk test, and will only deactivate when all
detectors have been tested.
0049
Detector
Masked
If any detector goes into ‘mask’
condition the output will trigger
When masking fault clears.
0050 Follow
24
Hour
If any input programmed as “Day
alarm” activates
When input restored
0051 Line
Fault
When Line Fault signalled by
communicator
When fault clears
0052 Mains
Fail
After pre-set time without mains
power
On restoration of mains
0053 Battery
Fault
When battery disconnected or load
fail detected
At next valid code entry
0054 Low
Volts
At fault
When fault clears
0055
Global Fault 1
(Faults: Modem,
Battery, Fuse,
Line, Mains)
Activates if fault occurs only when
system is armed
When all faults cleared
0056
Global Fault 2
(Faults: as
above)
Activates if fault occurs at any time When all faults cleared
0057 German Relay
Relay for specific applications -
Generally not used
0058
Guard Code
Used
When ‘guard’ code accepted
After 60 seconds
0059
Engineer
Access
When entering Engineer Mode
Leaving Engineer Mode
0060 Initialise
Digi
At power up
Live for 45 seconds only
0063 Test
ATE/GSM
Test signalling through PSTN and
GSM. Activates when a test call is
sent.(only used for specific GSMs)
When test completed
0064
Test ATS
For use with ATE
complying with
BSIA Form 175
to initiate test
call to ARC by
each available
path.
Test signalling through PSTN and
GSM. Activates when a test call is
sent.
When test completed