Page | 46
2 Key HU
cont...
None:
Inactive.
Silent:
Silent Hold Up.
Bells Only
: Bells Only (No
signalling).
Both:
(Signalling and Bells)
EURO 280 keypads do not comply with ACPO requirements for this
facility to be used for police calls.
Extl ATE Inputs
None
Permits selection of inputs to ATE pins to suit ‘ATE’ (including Red
Care Reset), ‘DigiCom’ (including Telback), ‘Relay Interface
Monitoring’ or ‘Not Used’.
Note: This option must be set to ‘STU’ or
‘Digi’ in order for Line Fault, etc. monitoring to function. This option is
NOT required for use with the digi-modem.
Tag Opens
Doors
No
Used in conjunction with “Entry Control” in Assign Keypads/Readers
(Page:23). If set to ‘No’ – any reader assigned for ‘entry control’ will
arm/disarm as normal, and any doors on the system are open when
the system is unset. If set ‘Yes’ the readers control the
arming/disarming and doors.
Set with
Polling Fault
No
If ‘
YES
’ the system will set regardless if there is a wireless ‘polling’
fault or not (a wireless device can no longer communicate with the
wireless expander).
Fob Unset
Entry
Yes
If ‘
YES’
allows the use of the wireless keyfob to only unset the
system once an entry time has been initiated. If this is ‘
NO
’, a
wireless keyfob will unset the system without an entry time.
Wireless Bell
Supervision
Yes
If ‘
YES
’ then the wireless bell will activate if it can no longer
communicate with the Wireless Expander.
Download if
Set
No
If ‘
YES
’ then upload/downloading will be possible regardless if the
panel is set or unset.
Unset Alert
Yes
If ‘
YES
’ then the keypad will give an audible alert after the system is
unset with a keyfob –
and
has been in alarm or fault (so that this
does not go unnoticed by people not viewing the panel or keypad)
Site Options
Using the
and
keys, scroll
to
‘SITE OPTIONS
’.
Press the
key
Set With Fault
Enter
: for
No.
Enter
: for
Yes.
Press the
key. Repeat for all
other options until:
2 Key HU
Enter
: for
Silent.
Enter
: for
Bells Only.
Enter
: for
Both.
Enter
: for
None
Press the
key.
External ATE Inputs
Enter
: for
STU
,
: for
Digi
Enter
: for
Both
,
: for
None
Press
for the Engineer Menu.