6-8
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Troubleshooting
•
COMM - Communications
•
XOVER - Crossover Protection: One PA Controller crosses over to protect the
PAs controlled by another PA Controller, should it become inoperative (only used
with optional Z2 Redundancy Package).
•
PSC - Power Supply Controller
•
DSCHG - Discharge
•
Start - Soft Start
•
HS - Heat Sink
•
PHS_LS - Phase Loss
•
OV - Over Voltage
•
UV - Under Voltage
•
TAP# - Power Supply SCR TAP # (TAP1, TAP2, TAP3, or TAP4)
6.6.4
Fault Listing
Tables 6-1, 6-2, and 6-3 provide a quick reference, containing a complete listing of
all of the faults which can show up on the Diagnostics Display Menu, including
their effect on transmitter operation and a brief comment explaining the fault.
•
Table 6-1 includes faults that are associated with the Master Controller Board
(which includes the IPA).
•
Table 6-2 includes faults that are associated with the PA Controller Board, PAs
and ISO Loads.
•
Table 6-3 includes faults that are associated with the PS Controller Board and the
power supply itself.
These tables are meant as a summary and quick reference point. The rest of this
section will be dedicated to giving detailed information on each of these faults.
6.7
Self Diagnostics
The Z Series transmitter is equipped with a set of TEST menus for testing various
internal systems. To access the TEST menus press [MORE, TEST]. This brings you
to the screen in Figure 6-4. This screen gives you 2 choices:
•
SYSTEM TEST
•
CONTROL HARDWARE
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...