2-18
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
2.6
Initial Turn-on
Each transmitter is thoroughly checked out during factory final test but adjustment
may be required during installation due to shipping, variations in primary power,
antenna systems, or transmission line differences. Any remote or extended control
connections should be connected only after the transmitter is checked out and fully
operational.
Refer to the Factory Test Data Sheets supplied with the transmitter for typical meter
readings. The transmitter was checked into a 50-ohm resistive load at the Factory.
The Transmitter ON-OFF sequence is controlled by three separate buttons:
•
HIGH
•
LOW
•
OFF
These buttons are located on the front panel of the Controller.
Step 1: Activate the STATION AC POWER source to the transmitter.
Step 2: Turn on the low voltage power supply breaker, CB1, located in the rear of
the transmitter cabinet in the upper right-hand corner. There are 6 green LEDs on
the Low Voltage Supply board which should be illuminated. Close and secure the
rear door.
Step 3: Verify that the two LCD displays on the front of the controller are active.
The Diagnostics display should look like Figure 2-7. The Fault LED on the front
panel will be lit, since the modules are not installed yet, and should be ignored at
this point.
Figure 2-7
Default Diagnostics Display Screen
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...