888-2406-002
2-9
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
NOTE:
Terminals 1 and 2 are connected inside the Wago block as are terminals 3 and
4 and terminals 5 and 6. This allows for connections to the second supply on
the output side of the Wago block.
j.
The +52Vdc output and ground from the second supply must also be con-
nected. Wire #52 connects to feedthru C4. Ground wire #60 connects to the
ground stud at the top front of the power supply compartment (above C3 and
C4). See Figure 2-2.
2.5.5
Single Phase Power Supply Installation
Before installing the power supply check the primary AC tapping on the power
transformers as outlined below. Even if the transmitter was shipped with the power
supply installed, it would be a good idea to check the power supply tapping if
possible.
2.5.5.1 Power Transformer Tapping
The power transformers are tapped at the factory for the primary AC voltage
specified by the customer. This voltage should be documented in the factory test
data accompanying the transmitter and tagged at the AC contactor. However, the
voltage at the site and the transformer tapping should be verified by the installation
personnel. The input voltage and strapping chart is shown on the Overall System
Block Diagram along with the transformer schematic. Verification and/or re-tapping
will require opening the power supply access panel on the front of the transmitter
and rolling out the power supply if the transmitter was shipped with the power
supply already installed (this depends on where and how it is shipped).
2.5.5.2 Power Supply Connections
First, remove the front cover panel from the power supply compartment at the
bottom of the transmitter. The power supply connection cables are either tied up in
the power supply compartment (in the bottom of the transmitter) or tied up with the
power transformers. The power supply should be rolled into position in front of the
transmitter, then carefully rolled into the transmitter making sure that none of the
interconnect cables get caught on the power supply tray.
The following cables will need to be connected:
a.
There is one ribbon cable and one power connector hanging on the right side
of the power supply compartment inside the transmitter. The ribbon cable
connects to J4 on the Rectifier Board. Be sure to route this cable so it does not
touch the resistor located on top of the Rectifier board. The power cable (the
gray cable with the orange connector) connects to J6, on the Rectifier Board
near the front of the transmitter. See Figure 2-4.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...