WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
NOTE:
The REF VOLTAGE in Figure 2-19 is merely an internal reference point the
controller uses to reduce the supply voltage in optimized mode. This reading
is usually in the low 40’s when the transmitter is optimized (well below the
actual supply voltage).
2.10 Setting the Low Power Alarm
The transmitter has a low power alarm output for a remote control system. The
power level at which this remote alarm output is triggered, at TB1-13
XMTR_PWR_LO_IND, is selectable in the Configuration Menus. To set this power
level press [HOME, MORE, CONFIGURATION B,D,B]. This should take you to
the screen in Figure 2-20. Set the power level at which you want the alarm to
become active and press [BACK] to save changes. For a complete listing of all
configurable parameters see “System Configuration and Calibration” in Section VI,
Troubleshooting.
Figure 2-20
Remote Low Power Alarm Set
[HOME, MORE, CONFIGURATION B,D,B
2.11 Jumper Settings for Installation of a Harris Exciter
The following is for installing an exciter other than the one (or two) which came
with the transmitter. Any exciter tested and shipped with the transmitter will have
already been configured properly for the transmitter and should not require any
jumper changes (Mounting kits are available for each of the exciters).
Table 2-2 includes all relevant jumper placement for the transmitter and the
following exciters:
•
Digit CD Exciter with 994-XXXX-004 part number.
•
Digit Exciter with 994-XXXX-002 part number.
•
SuperCiter
•
THE-1
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...