2-4
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
b.
Controller Connections
1.
Check the Ribbon cables connected to the back of the controller boards
and to the exciter(s).
2.
Make sure that all of the boards in the controller are properly seated in
the backplane (motherboard) connector.
2.5.3
Exciter Installation
The exciter may or may not be removed from the transmitter depending on the
shipping considerations. If the exciter was not removed for shipping, then all
transmitter connections will already be hooked up. The audio input connections and
level adjustments can be found in the exciter manual accompanying the transmitter.
The exciter input cables should be installed in a metal conduit which is separate
from the AC supply.If the exciter was removed for shipping, there are three cables
which will need to be hooked up (not counting the audio inputs).
a.
A ribbon cable which will hook to the remote control connector on the back
of the exciter. This is A10-J2 on the SuperCiter and J2 on the ‘DIGIT.
b.
A coaxial cable with a male BNC connector which connects to the exciter RF
output. This is A10-J11 on the SuperCiter and J1 on the DIGIT.
c.
AC Power Cable. Verify that the exciter is set for the correct operating volt-
age. For more information refer to the Exciter Manual, Section II, Installation.
NOTE:
For Digit Exciters, the VCO shipping screws must be removed as outlined in
the exciter manual in Section II.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...