888-2406-002
6-33
WARNING: Disconnect primary power prior to servicing.
Troubleshooting
Table 6-3 Z2 or Z2R Master Controller Related Faults
ABBREVIATION
COMMENT
ACTION
MSTR_REF
+5V reference fault. Ind5V reference
is < 4.6V
Mute XMTR (IPA & Exciter, Power
supplies)
REF_WARNING
Ind5V Reference is out of tolerance
at the Master Controller Board with error of
more than 0.25V but < 0.4V
Reports fault in Log without shutting down
the PAs.
RFL_PWR
Reflected power has exceeded VSWR
overload threshold
Will follow 3 Strike Routine (described in
Section 6) Transmitter will mute and try to
slowly ramp power back up to normal.
INTLK
External Interlock fault
Turn off XMTR, light INTERLOCK LED
FAILSAFE
Failsafe fault, AC on and power supply in
standby mode
Mute XMTR, blink INTERLOCK LED
POWER_FAIL
AC power supply failed, +20V power supply
on Life Support Board is less than 12V.
Mute XMTR & save fault time. Transmitter
will automatically return to operation when
power returns.
LOW_AIR
Low air flow fault at 25% (88 cf/m)
Low-fan TO high-fan, OR high-fan TO AC
off
UPS
Logic LOW detected at Remote UPS input
Transmitter is switched to the UPS
Forward Power setting
CPLR_NC
Forward power Directional coupler cable is
not connected
Mute XMTR. Restart required to restore
power
IPA1_MUTE
IPA_AB1 current still present with Vg < -15V
Mute XMTR (exciter and PAs)
IPA1_LOW
IPA_AB1 power is < 30% of calibrated output
with Vg = 0V
Mute, then switch to other IPA
IPA1_OC
IPA_AB1 current has exceeded the 14.5A
threshold
Mute, then switch to other IPA
IPA1_TW
IPA Temperature Warning, IPA_AB
temperature > 85
o
C
Switch fan to high speed
IPA1_OT
IPA_AB1 temperature has exceeded 100
o
C
Mute, then switch to other IPA
IPA1_OUT
IPA_AB1 is not inserted completely into the
connector
Switch to IPA_AB2 if it is not faulted
IPA2_MUTE
IPA_AB2 current still present with Vg < -15V
Mute XMTR (exciter and PAs)
IPA2_LOW
IPA_AB2 power is < 30% of calibrated output
with Vg = 0V
Mute, then switch to other IPA
IPA2_OC
IPA_AB2 current has exceeded the 14.5A
threshold
Mute, then switch to other IPA
IPA2_OT
IPA_AB2 temperature has exceeded 100
o
C
Mute, then switch to other IPA
IPA2_OUT
IPA_AB2 is not inserted completely into the
connector
Switch to IPA_AB1 if it is not faulted
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...