2-10
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
Figure 2-4
Single Phase Power Supply Top View
b.
The cable labelled A1P2 (gray and yellow multi-conductor cable with gray
connector) plugs into its mating connector on the left wall of the power sup-
ply compartment, see Figure 2-4.
c.
Wires #1 and #2 (orange cables tied up on the left side of the power supply
compartment) and wires #40 and #41 plug into the gray Wago block connec-
tor on the front of the power supply tray. See Figure 2-4.
d.
The wago block has 4 terminals labelled terminal #1 on the left and #4 on the
right. The connections are as follows:
1.
Wire #1 connects to terminal #1
2.
Wire #2 connects to terminal #2
3.
Wire #40 connects to terminal #3
4.
Wire #41 connects to terminal #4
To insert the wires into the wago block,insert a screwdriver into the rectangular slot
behind the wire hole and then carefully push toward the rear of the transmitter. This will
open the contact inside the wago block and the wire can be inserted. Be very careful not to
let the wire ends fray as the connectors are very close together and could cause a short.
The wire insulation should actually extend just inside the Wago block hole.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...