2-16
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
may show up as noise or feedback. Wire and cable shields should normally be
connected at both ends to the equipment chassis.
A ground strap attachment point is located on the top, right rear, of the cabinet (use
four 1/4-20 brass screws with brass washers). Use this connection when utilizing a
single point grounding system, attaching your ground strap to the common
grounding plate. An alternate ground connection is a short copper strap on the back
of the Platinum Z transmitter, on the bottom right side. Unfold this strap and
securely bolt or silver solder it to the building ground. This strap can be removed
from the bottom and used at the top.
A grounding stud is also provided near the AC input connections in the upper
portion of the Platinum Z transmitter. Use this connection for the power line ground.
It is located above the low voltage power supply board.
2.5.6.5 Low Voltage Power Supply and Blower
The Low Voltage Power Supply and the blower motor operate from any voltage
within the specified range of the tapping chart without re-tapping.
2.5.6.6 Exciter AC Voltage Selection
Once the site voltage has been checked, verify that the exciter(s) are set for the
proper input AC voltage. For verification, the selected voltage should be visible
next to the AC power cord connection on the rear of the exciter. The voltage at the
exciter AC input can be found by measuring between any two phases of a 3 phase 3
wire system or any phase to Neutral in a 3 phase 4 wire system. If single phase
power is used the exciter should be set to the same as the AC line voltage. For more
information on setting the exciter voltage, refer to the exciter technical manual.
2.5.7
RF Output Connection
The station transmission line may now be connected at the 1 5/8" EIA flange
located on top of the transmitter. Be sure the bullet seats correctly and all flange
bolts are tight. Make sure the clamp at the top of the harmonic filter is tightened.
2.5.8
Audio Input Connections
All audio signals connect directly to the back of the exciter(s) by routing the cables
through the top or bottom of the transmitter. The exciter technical manual has all of
the information pertaining to audio connections, input levels and adjustments. Be
sure to leave enough cable slack to allow the exciter to be pulled all of the way out
on the rack slides.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...