888-2406-002
5-21
WARNING: Disconnect primary power prior to servicing.
Maintenance and Alignment
5.14 System Configuration and Calibration
System configuration and calibration is mainly for setting the transmitter up for the
first time by factory personnel. The procedures contained here should NOT be done
as part of a routine maintenance or adjustment schedule. The following procedure
should only be done if EEPROM U39 on the Master Controller Board is bad or
suspect (EEPROM U39 is the memory chip which contains all of the transmitter
configuration and calibration settings). Replacement of the Master Controller Board
can be accomplished by swapping U39 from the old board to the new one. See
“Replacing the Master Controller Board” earlier in this section before proceeding.
The procedure will be broken up into two sections;
a.
Configuration
b.
Calibration
5.14.1 Configuration
The transmitter should be turned off, but with AC power applied from the wall
breaker. The REMOTE DISABLED LED should be lit on the front panel of the
transmitter. For the following setup refer to the Diagnostics Display Menu Tree for
more details of how to get to System Calibration and Setup screens referred to in the
following steps.
NOTE:
For the following procedures do not press [HOME] or [BACK] unless specif-
ically told to do so.
STEP 1
Press [HOME, MORE, CONFIGURATION A] From here the
following System choices need to be made:
•
ALTERNATE EXCITER: Yes or No (“Yes” if there is an second
alternate Exciter in the transmitter).
•
INTLK LOG: ON or OFF (ON if you want interlock faults to be
entered into the Diagnostics Display Fault Log, OFF if you do not
want the interlock faults entered into the Fault Log). Combined
transmitters should be set to OFF, while single transmitter installa-
tions should be set to ON. This can be changed later if so desired.
•
PSC Number - Number of Power Supply Controllers 1 or 2. This is
1 for a Z2 (2 for a Z2R).
STEP 2
Press [MORE] and then continue below.
•
AC PHASE: Select “1" phase or ”3" phase to match your transmit-
ter power supply configuration.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...