6-16
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Troubleshooting
!
CAUTION:
TURN OFF ALL POWER TO THE TRANSMITTER AT THE WALL BREAKER
BEFORE ATTEMPTING TO SERVICE THE BLOWER MOTOR. THE
THERMAL PROTECTION, INTERNAL TO THE MOTOR, IS AUTOMATIC. IT
WILL SHUT THE BLOWER OFF IF THE MOTOR TEMPERATURE GETS
TOO HIGH, BUT IT WILL ALSO AUTOMATICALLY TURN IT BACK ON
AFTER A FEW MINUTES AS THE TEMPERATURE GOES DOWN.
6.9.10 UPS, Uninterruptable Power Supply Fault
This fault indicates that the transmitter has switched over to the UPS (or generator
possibly). The transmitter power output is now controlled by the UPS Power Level
setting in the Configuration menus of the Diagnostics Display. To check or set the
UPS Power Level press [CONFIGURATION B,D,A]. The default factory setting is
1.00 kW. Use the ABCD keys to set a new UPS power level. Press [BACK] to save
any changes and [HOME] to cancel any changes.
6.9.11 CPLR_NC, Forward Directional Coupler Cable
Not Connected
This fault is active anytime the sample cable from the Forward power directional
coupler to the Life Support Board is disconnected. The fault immediately mutes the
transmitter until the cable is re-connected due to the effect this would have on the
APC loop.
6.9.12 IPA_#_MUTE, Fault
This fault could be for IPA_1 or IPA_2. Whenever the IPA is muted, the control
system checks the IPA current draw by the IPA amplifier. If the current is not less
than 1 amp, then the system does not have the ability to shut off the IPA and will
mute the system by shutting off the PAs and the exciter.
6.9.13 IPA_#_LOW, Fault
If one of the IPAs should be putting out power, but is not according to the IPA
directional coupler sample (from the IPA Backplane Board), then a 3 strike routine
is initiated. If the fault is still present, the controller will switch to the second IPA
(provided it has not previously faulted off). The controller looks to see if the exciter
or IPA is muted before reporting this fault.
6.9.14 IPA_#_OC, Fault
This IPA Over-Current fault could be for IPA_1 or IPA_2. The overcurrent
threshold is 14.5 amps. If this IPA current limit is exceeded, the transmitter will
initiate a 3 strike routine. If the IPA in question is still faulted, the transmitter will
automatically switch over to the second IPA.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...