WARNING: Disconnect primary power prior to servicing.
Maintenance and Alignment
5.13.2 Replacing the Power Supply Controller Board
Replacement of a PS Controller Board requires no analog adjustments. Set all dip
switches and jumpers to the same position as the board being replaced. If the new
board does not have the firmware IC’s already installed, then the firmware will have
to be transferred from the old board. Refer to “Removing and Replacing Firmware
ICs” later in this section.
The following is a listing of the normal dipswitch and jumper settings:
a.
For PSC #1 - All switches OFF
b.
For PSC #2 - S1-1 ON, all other switches OFF (PSC #2 is optional and only
used as part of the Z2R Redundancy package).
c.
JP1 pins 1-2
d.
JP2 pins 1-2
5.13.3 Replacing a PA Controller Board
Replacement of a PA Controller Board requires no analog adjustments. Set all dip
switches and jumpers to the same position as the board being replaced. If the new
board does not have the firmware IC’s already installed, then the firmware will have
to be transferred from the old board. Refer to “Removing and Replacing Firmware
ICs” later in this section. The following is a listing of the normal dipswitch settings
for S1 on each PA Controller:
For the Standard Z2:
a.
For PAC #1 - S1-4 = ON, all other switches OFF.
b.
For PAC #2 - S1-1 and S1-5 = ON, all other switches OFF.
For the Z2R:(Redundancy Package)
a.
For PAC #1 - S1-5 = ON, all other switches OFF.
b.
For PAC #2 - S1-1 and S1-5 = ON, all other switches OFF.
NOTE:
The switches set the board ID #. Once the ID for the board has been set, it
must be placed in the proper slot and the correct cables connected to that #
controller. An improper ID or incorrect cabling will generate cable or jumper
faults in the Fault Log and the transmitter will not turn on.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...