4-56
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
e.
MSTR_NORMAL 1 applies a low to NAND gate U7-2 causing U7-3 to go
high. This enables the direct connection of the front panel overlay buttons to
the on and off logic by enabling U26-13 and U26-2, bypassing the control cir-
cuits on the failed Master Controller.
1.
When the OFF button is pressed, U26-1 will go high, causing U26-3 to
go high. This then passes through a series of OR gates, U31-8, U31-11
and U33-6 and on to U16-10. This then connects to the RESET line on
latching relay K4, placing it in the position shown on the schematic.
K4-13 will go low, and this is sent through U16-12 and on to the LOW
Voltage Power Supply Board to relays K1 and K2. K1 and K2 will
both open, shutting off the AC to the contactor and the exciters (K1
applies AC to the contactor coil, while K2 applies AC to the exciters).
2.
The high at U26-13 enables the XMTR_ON_LOW pushbutton on the
front panel overlay when in Life Support Mode to enable the local
transmitter ON LOW command. Remote ON LOW (REM_ON_LOW)
is also available in Life Support Mode. Note that the HIGH ON push-
button on the front panel overlay has no function when in Life Support
Mode.
f.
MSTR_NORMAL 1 applies a low to all four AND gates in both U12 and
U14. This prevents the Master Controller from applying exciter mute, exciter
select or IPA select signals.
4.7.6.2.1.3 MASTER_NORMAL(BAR)
This signal goes high when the Master Controller fails. It causes the following
actions to occur:
a.
MASTER_NORMAL(BAR) applies a high to AND gate U6-2. This enables
the fault, LS_SYST_FAULT (Life Support System Fault) only while in Life
Support Mode. This fault is caused by excessive VSWR or IPA Current and
will shut the transmitter off.
b.
MASTER_NORMAL(BAR) applies a high to OR gate U32-5. This enables
the remote command, REM_ON_LOW(BAR) so the transmitter can be
turned on by remote control when the Master Controller has failed. Note that
the REMOTE_ON_LOW(BAR) command can be disabled, during normal
operation, by placing the controller in LOCAL mode using the front panel
REMOTE DISABLE pushbutton. This disables the remote ON command via
the REM_ON_ENABLE signal at U32-4. If the Controller is in LOCAL
mode, U26-5 will be low and the REM_ON_LOW(BAR) command is inhib-
ited. When Life Support Mode is initiated, U32-5 and therefore U26-5 is
forced high enabling the REM_ON_LOW(BAR) command.
Summary of Contents for Platinum Z2 CD
Page 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Page 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Page 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Page 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Page 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...