Page 1: ...t a m s e l e k t r o n i k Manual Transformer 50 VA 16 V Item no 70 09030 01 Transformer 52 VA 12 18 V Item no 70 09021 01 tams elektronik n n n ...

Page 2: ... 6 Transformer 52 VA 12 18 V Technical specifications 9 7 Guarantee bond 10 8 EU declaration of conformity 11 9 Declarations conforming to the WEEE directive 11 08 2020 Tams Elektronik GmbH All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying without prior permission in writing from Tams Elektro...

Page 3: ...ding to the instructions in this manual with model railways and in model building Any other use is inappropriate and invalidates any guarantees The transformers are not intended to be installed by children under 14 years of age Reading understanding and following the instructions in this manual are mandatory for the user Please note Non observance of the manual may cause damage to your transformer...

Page 4: ...d or damaged by sharp edged objects If the housing or the insulation of the mains cable is damaged do not continue to use the transformer Protect from overheating Ensure that the transformer is able to release the heat generated during operation to the ambient air Therefore never cover or install it Otherwise the transformer may overheat Protect it from falling down Always place the transformer on...

Page 5: ...ransformer has holes to accommodate fastening screws Never screw screws directly into the housing of the transformer Connecting the loads When connecting the supply lines to the loads make sure that the line cross section is sufficient Overloading the connecting cables can cause overheating and fire hazard The terminals on the transformer are intended for connecting the consumers Press the pushbut...

Page 6: ...ransformer is not sufficient in the example shown the booster is supplied by two transformers connected in parallel This connection is not recommended Wiring errors which can result from ignorance or accident carry considerable risks There is a danger that the recovery of the input voltage could result in a dangerous touch voltage For toy transformers e g transformer 52 VA 12 18 V this danger is r...

Page 7: ... for the connection After the formation of condensation water wait until the condensation has evaporated before starting up This can take several hours 4 Operation The transformer has a thermal protection switch that automatically switches off the unit in case of overload or overheating The transformer can only be put back into operation after it has cooled down completely duration at least 30 min...

Page 8: ...equirements of DIN EN 62115 Electrical toys Safety and is therefore not intended to be connected by children under 14 years of age Page 8 Total power max 50 VA Input voltage 230 V Frequency 50 60 Hz Output voltage 16 V AC Output current Max 3 125 A Insulation class Ta 40 C E Temperature switch 110 C Protection class II Protected to IP40 Dimensions length x width x height approx 100 x 60 x 62 mm We...

Page 9: ...1558 Short circuit proof Meets the requirements of DIN EN 62115 Electrical toys Safety Page 9 Total power max 52 VA Input voltage 230 V Frequency 50 60 Hz Output voltage 0 12 18 V AC Output current Max 2 9 A Insulation class Ta 40 C E Temperature switch 110 C Protection class II Protected to IP40 Dimensions length x width x height approx 130 x 70 x 50 mm Weight Approx 1 270 g cable included ...

Page 10: ...y us or to manufacturing defects We guarantee the adherence to the technical data in case of prescribed commissioning and operation We reserve the right to repair rectify replace or refund the purchase price Further claims are excluded Claims for compensation for consequential damage or from product liability exist only in accordance with the statutory provisions A prerequisite for the effectivene...

Page 11: ...ctrical and electronic equipment RoHS amended by Directives EU 2015 863 and 2017 2102 Underlying standard EN 50581 2004 108 EC on electromagnetic compatibility Underlying standards EN 55014 1 and EN 61000 6 3 The 52 VA 12 18 V transformer also meets the requirements of the EU Directive 2009 48 EC on toys Underlying standard EN 61558 2 7 9 Declarations conforming to the WEEE directive This product ...

Page 12: ... Not suitable for children under 14 years http www tams online de n n n n Made in Germany Warranty and service n Tams Elektronik GmbH n Fuhrberger Straße 4 DE 30625 Hannover n fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 n e mail modellbahn tams online de n n ...